ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway
allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled
PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly
every industry and include SCADA systems and Power Monitors. Four Serial ports
allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of
gateways required for your application.
In addition, the gateway includes several features that allow for simplified integration,
reduced commissioning time and optimized performance.

Product Dimensions:

ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway
allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled
PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly
every industry and include SCADA systems and Power Monitors. Four Serial ports
allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of
gateways required for your application.
In addition, the gateway includes several features that allow for simplified integration,
reduced commissioning time and optimized performance.
Features
 Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
 Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your
application.
 Supports up to 20 simultaneous client & server connections, allowing for faster communication between devices such as HMIs,
SCADA systems, power monitors and flow computers, among others.
 ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the
same subnet as the module.
 Secure module configuration via module switch (v1.04 and greater).
 Up to 10,000 16-bit registers can be used to exchange large amounts of data.
Specifications
Modbus® TCP/IP Specifications
Specification Description
Supported Modbus
Function Codes
1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single
Holding Register
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple
Holding Registers
22: Mask Write Holding Register
(Slave Only)
23: Read/Write Holding
Registers (Slave Only)
Supported Clients 10
Supported Servers MBAP: 5
Encapsulated: 5
Command List Up to 160 fully configurable Client commands
Status Data Error codes reported individually for each command
Command List Polling Each command can be individually enabled or disabled;
write-only-on-data-change is available
Modbus Serial Specifications
Specification Description
Command List Up to 100 commands per Master port, each fully configurable
for Function Code, slave address, register to/from addressing
and word/bit count.
Supported Modbus
Function Codes
1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single
Holding Register
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple
Holding Registers
22: Mask Write Holding Register
(Slave Only)
23: Read/Write Holding
Registers (Slave Only)
Software configurable
communication
parameters
Baud rate: 110 baud to 115.2 kbps
Parity: None, Even, Odd
Data Size: 7 or 8 bits
Stop bits: 1 or 2
RTS on/off delay: 0 to 65535 milliseconds
Modbus RTU mode (binary) with CRC-16
Modbus ASCII mode with LRC error checking
Floating Point Data Floating point data movement supported,
including configurable support for Enron and Daniel
implementations
Polling of Command List Configurable polling of command list, including continuous
and on change of data, and dynamically user or automatic
enabled.
Status Data Error codes available on an individual command basis. In
addition, a slave status list is maintained per active Modbus
Master port.
Node Address 1 to 247 (software selectable)
RS Interface RS232, RS422, and RS485
Transmit and Receive
Buffer Size
255 byte Transmit character length with 0 to 65535
millisecond delay between each transmitted character
Where Automation
Connects™
Global Distribution
ProSoft Technology® products are
distributed and supported worldwide
through a network of over 500
distributors in over 50 countries.
Our knowledgeable distributors are
familiar with your application needs.
For a complete list of distributors,
go to our website at:
www.prosoft-technology.com
Global Support
We are there for you
All ProSoft Technology products are
backed with free technical support.
Contact our worldwide Technical
Support team directly by phone or
email.
Global Offices
We are where you are
ProSoft Technology has regional
offices worldwide available to help
you with all your industrial
application needs. If you need help
choosing a ProSoft Technology
solution for your particular
application, check out our contact
information under distributor sales
on the website at:
www.prosoft-technology.com
Whether your application is large or
small, our technical professionals
are there to help you choose the
right communication solution.
Hardware Specifications
Specification Description
Power Supply 24 VDC nominal
10 to 36 VDC allowed
Positive, Negative, GND Terminals
Current Load 24 VDC nominal @ 300 mA
10 to 36 VDC @ 610 mA maximum
Operating Temperature -25°C to 70°C (-13°F to 158°F)
Storage Temperature -40°C to 80°C (-40°F to 176°F)
Shock IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)
Vibration IEC 60068-2-6; 5G @ 10 to 150 Hz
Relative Humidity 5% to 95% RH with no condensation
Dimensions (H x W x D) 5.38 x 1.99 x 4.38 in
13.67 x 5.05 x 11.13 cm
LED Indicators
Configuration (CFG), Error (ERR), Power (PWR), Hardware
Fault (FLT), Network Status (NS), EtherNet/IP™ Class I or
Class III Connection Status (EtherNet/IP Only) Module
Status (MS), Module Configuration Status (EtherNet/IP Only)
Ethernet Communication Port Link/Activity, and 100 mbit
Serial Communication Port Receive (RX) and Transmit (TX)
Ethernet Port
10/100Mbit full- and half-duplex RJ45 Connector Electrical
Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied
as specified in section 5.3.2 of IEC 60950: 1991 Ethernet
Broadcast Storm Resiliency is less than or equal to 5000
[ARP] frames-per-second and less than or equal to 5 minutes
duration
Number of Serial Ports 4
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577. Serial port
communication signal uses RF (Radio Frequency)
modulation signal as isolation media.
Shipped With Each Unit 2.5 mm screwdriver
J180 Power Connector
(4) RJ45-DB9M Serial Adapter Cable (serial protocol)
(4) DB9 to Screw Terminal Adapter (serial protocol)
Enclosure Rating IP20, NEMA/UL Open Type, DIN Rail

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

PROSOFT MVI56-GSC
PROSOFT MVI56-LTQ
PROSOFT MVI56-PDPMV1
PROSOFT MVI69-MNET
PROSOFT MVI94-GSC
PROSOFT MVI56-MCM
PROSOFT MVI94-MCM
PROSOFT MV156-PDPMV1
PROSOFT AN-X2-AB-DHRIO
PROSOFT PLX31-EIP-MBTCP
PROSOFT MVI56E-MCM
PROSOFT MVI69E-MBTCP
PROSOFT MVI46-PDPS
PROSOFT MV156E-MCMR
PROSOFT MVI46-ADMNET
PROSOFT MVI69E-MBS
PROSOFT MVI56E-MNET
PROSOFT MV169-MCM
PROSOFT MVI46-MCM
PROSOFT MVI56E-MNET
PROSOFT MVI56-EGD
PROSOFT MVI69-MCM

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm