Description
TV809 SINEAX Isolating Amplifier/Transducer
Product Dimensions:
Product Description (Detailed Explanation)
The SINEAX TV809 serves as a vital interface in industrial automation. Its primary function is to resolve “ground loop” problems and provide galvanic isolation between the input, output, and power supply. This prevents potential differences from damaging sensitive PLC/DCS inputs or distorting measurement data.
The device is highly versatile, featuring a wide range of programmable or switch-selectable input and output configurations (such as 0–20 mA, 4–20 mA, or 0–10 V). It is housed in a compact, DIN-rail mountable enclosure, making it ideal for dense electrical cabinets.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Input Signals | DC Current (up to 50 mA) or DC Voltage (up to 1000 V) |
| Output Signals | DC Current (0/4–20 mA) or DC Voltage (0/2–10 V) |
| Galvanic Isolation | 3-way isolation (Input / Output / Power) |
| Isolation Voltage | 2.3 kV AC / 50 Hz (1 minute) |
| Response Time | < 50 ms (typical) |
| Power Supply | Multi-range: 24–60 V AC/DC or 85–230 V AC/DC |
| Accuracy | Class 0.2 (±0.2% of span) |
| Mounting | 35 mm DIN Rail (Top-hat rail) |
Product Advantages (Key Benefits)
-
3-Way Isolation: Provides total separation between the power source, the measurement source, and the receiving device, protecting the entire signal chain.
-
Universal Power Supply: The broad power input range reduces the number of variants needed for international projects, simplifying spare parts inventory.
-
High Precision: With a 0.2% accuracy class, it ensures that the integrity of the process variable (temperature, pressure, etc.) is maintained during conversion.
-
Signal Conversion: It can act as a converter (e.g., transforming a 0–10 V sensor signal into a 4–20 mA current loop for long-distance transmission).
-
Compact Design: The slim profile saves significant space on the DIN rail in crowded control panels.
Precautions (Important Notes)
-
Configuration: Ensure the DIP switches (if applicable) or programming parameters are set correctly to match your specific input/output requirements before applying power.
-
Load Resistance: Check the maximum allowable load resistance (burden) for current outputs to ensure the signal does not drop out over long cable runs.
-
Terminal Tightening: Use appropriate torque for terminal screws to prevent loose connections, which can lead to signal flickering or intermittent faults.
-
Environmental Limits: Avoid installing the unit in areas with high ambient temperatures beyond the rated specifications without ensuring adequate ventilation or spacing between modules.
Product Applications (Typical Use Cases)
-
Ground Loop Elimination: Resolving measurement errors caused by potential differences between two grounded points in a large industrial plant.
-
Signal Level Matching: Converting specialized sensor outputs (like high-voltage DC) into standard 4–20 mA signals for a PLC.
-
System Protection: Shielding expensive control systems (DCS) from high-voltage surges or electrical noise originating in the field.
-
Power Plants & Utilities: Monitoring battery voltages or DC current in substations where high galvanic isolation is a safety requirement.
-
Water Treatment: Isolating signals from flowmeters or pH sensors that are submerged and prone to electrical interference.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
| ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
| ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
| ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
| ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
| ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
| Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
| ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
| ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
| ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
| ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
| ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
| Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
| ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
| ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
| ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
| ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
| ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
| ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
| ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
| ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
| ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
| ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
| ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
| ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
| AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
| AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
| AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
| AGILENT G2630-66015 |