Description
SPXCDULNTXF Honeywell Sensepoint XCD Flammable/IR Gas Transmitter
Product Dimensions:
Product Description (Detailed Explanation)
The Sensepoint XCD series provides a comprehensive solution for detecting flammable, toxic, and Oxygen gas hazards. The SPXCDULNTXF model specifically integrates the following:
-
Transmitter Body: A rugged, flameproof enclosure (usually aluminum or stainless steel) that houses the electronics and the display.
-
Sensor Technology: It utilizes Electrochemical cell technology to detect either Oxygen deficiency or specific toxic gases (such as $H_2S$, $CO$, $Cl_2$, etc.).
-
User Interface: Features a tri-color backlit LCD (Green for normal, Yellow for fault, Red for alarm) that allows for “non-intrusive” operation, meaning you can calibrate the device using a magnetic wand without opening the enclosure.
-
Certification: The “UL” in the part number indicates compliance with Underwriters Laboratories standards for use in Class I, Div 1 hazardous locations.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Detection Technique | Electrochemical (Toxic/Oxygen) |
| Input Voltage | $16 V DC$ to $32 V DC$ (24V nominal) |
| Output Signals | 4-20mA (Source or Sink) and 2 Programmable Alarm Relays + 1 Fault Relay |
| Digital Communication | MODBUS RTU (Optional on some models) |
| Housing Material | Epoxy-coated Aluminum Alloy (or optional 316 Stainless Steel) |
| Ingress Protection | IP66 (Dust-tight and protected against powerful water jets) |
| Operating Temperature | $-40^circ C$ to $+65^circ C$ (varies by sensor type) |
| Entries | 2 x M20 or 2 x 3/4″ NPT cable entries |
Product Advantages (Key Benefits)
-
Non-Intrusive Operation: One-man calibration and adjustment can be performed via magnetic switches through the glass window, ensuring the explosion-proof integrity is never compromised during maintenance.
-
Tri-Color Backlight: The instant visual status (Green/Yellow/Red) allows operators to identify the safety status of a zone from a distance, even in poor visibility.
-
Plug-in Sensor Modules: The sensor is a “plug-and-play” module. If a sensor fails or reaches the end of its life, it can be swapped quickly without removing the transmitter from the wall.
-
Common Platform: The XCD transmitter is a “universal” platform; the same transmitter body can be used for Flammable, Toxic, or Oxygen sensors, reducing spare part inventory.
Precautions (Important Notes)
-
Sensor Lifespan: Electrochemical sensors have a finite life (typically 2–3 years). Regular “Bump Testing” is mandatory to ensure the sensor has not become “poisoned” or depleted.
-
Mounting Orientation: The sensor must always point downwards to prevent dust or moisture from accumulating on the sensor membrane.
-
Calibration Gas: Use only certified calibration gas cylinders. Ensure the flow rate is adjusted according to Honeywell’s specifications (typically $0.5 L/min$).
-
Wiring Safety: Ensure the power is isolated before making any connections to the relay terminals or the 4-20mA loop.
Product Applications (Typical Use Cases)
The SPXCDULNTXF is widely used in sectors where toxic gas leakage or oxygen depletion is a risk:
-
Oil & Gas Facilities: Monitoring for $H_2S$ (Hydrogen Sulfide) in refineries and offshore platforms.
-
Wastewater Treatment: Detecting $H_2S$ in pump stations or monitoring for Oxygen deficiency in confined spaces.
-
Chemical Plants: Monitoring for toxic process gases like Chlorine ($Cl_2$) or Carbon Monoxide ($CO$).
-
Manufacturing & Labs: Detecting Oxygen levels in rooms where Nitrogen or other inert gases are used in large quantities.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| HAMAMATSU | MVS-7000 | Honeywell | 51402645-200 |
| Honeywell | 51309204-175 | Honeywell | 51403776-100 |
| Honeywell | 51304465-100 | Honeywell | MC-PAOY22 |
| Honeywell | 51304493-250 | Honeywell | TC-ODK161 |
| Honeywell | 51304685-150 | Honeywell | 900P01-0001 |
| Honeywell | 51304453-150 | Honeywell | RM7838C1004 |
| Honeywell | 51305072-600 | Honeywell | TC-FPDXX2 |
| Honeywell | 51304511-100 | Honeywell | TC-PRR021 |
| HONEYWELL | 51304453-100 | Honeywell | 51195156-300 |
| HONEYWELL | 51304644-125 | Honeywell | 51400700-100 |
| HONEYWELL | 51304518-150 | Honeywell | 51401286-100 |
| HONEYWELL | 51304362-300 | Honeywell | J-DIM00 |
| HONEYWELL | 51304672-150 | Honeywell | J-MHM10 |
| HONEYWELL | 51304650-100 | Honeywell | J-MSC10 |
| HONEYWELL | 51304487-100 | Honeywell | 51195066-100 /HF-75632-F |
| HONEYWELL | 51304754-150 | Honeywell | C7027A 1049 |
| HONEYWELL | CC-PAIM01 | Honeywell | 51402573-150 |
| HONEYWELL | CC-PAIH01 | Honeywell | DC1030CR-101000-E |
| HONEYWELL | CC-PAOH01 | Honeywell | XC5010C |
| HONEYWELL | CC-TAOX01 | Honeywell | 51401437-301 |
| HONEYWELL | CC-TAIX01 | Honeywell | TC-LLMUX2 |
| HONEYWELL | CC-TDOB01 | Honeywell | FF-SB12E04K-S2 |
| HONEYWELL | CC-TDIL01 | Honeywell | FF-SB12R04K-S2 |
| HONEYWELL | MC-TAMR04 | Honeywell | TK-PRR021 |
| HONEYWELL | HONEYWELL10024/I/I | Honeywell | 10006/2/1 |
| HONEYWELL | 51410070-175 | Honeywell | DC120211101000 |
| HONEYWELL | CC-PAON01 | Honeywell | 51305072-100 |
| Honeywell | FF-SB14E064-S2 | Honeywell | 51305072-200 |
| Honeywell | TC-PRS021 | Honeywell | 51305072-300 |
| Honeywell | TC-CCN014 | Honeywell | 621-0021R |
| Honeywell | 51197593 | Honeywell | 620-3030 |
| Honeywell | TC-FPCXX2 | Honeywell | FDC220/C7027A. 1049 |
| Honeywell | TC-PCIC01K | Honeywell | 04973-X01-333-20-00-000-000 |
| Honeywell | TC-TCXBNC | Honeywell | 946 A4V 2D 2C0 380E |
| Honeywell | DC1040-CR701000-E | Honeywell | 51404223-001 |
| Honeywell | KSW24 | Honeywell | 51404203-002 |
| Honeywell | LSQA6B134 | Honeywell | IPC 620-15 |
| Honeywell | TK-PRS021 | Honeywell | 946-A4V-2D-2C0-380E |
| Honeywell | TK-CCR014 | Honeywell | 621-3560 |
| Honeywell | TK-IOLI01 | Honeywell | MU-TAIH14 |
| Honeywell | 621-0010-ARC | Honeywell | MU-TAOY22 |
| Honeywell | ML984 | Honeywell | XCL5010 |
| Honeywell | 51304337-150 | Honeywell | LS2D4L |
| Honeywell | TK-FTEB01 | Honeywell | ECEA1616R24 |
| Honeywell | 620-0083C | Honeywell | EC7830A1066 |
| Honeywell | 51196694-300/U1 | Honeywell | EC7890B1010 |
| Honeywell | 621-0020RC | Honeywell | LSYAC1E |
| Honeywell | C7012A1186 | Honeywell | FC-SDI-1624 |
| Honeywell | TC-RPCXX1 | Honeywell | FC-TSDI-1624 |
| Honeywell | TC-IAH161 | Honeywell | TC-OAV081 |
| Honeywell | 51402645-200 | Honeywell | 80363972-150 |