Description
SCXI-1326 NI High-Voltage Terminal Block
Product Dimensions:
Product Description
The NI SCXI‑1326 (Part Number: 777687‑26) is a shielded high‑voltage screw terminal block designed for NI’s Signal Conditioning eXtensions for Instrumentation (SCXI) platform. It serves as a rugged, front‑mount interface between SCXI signal conditioning modules (e.g., SCXI‑1162, SCXI‑1162HV, SCXI‑1163, SCXI‑1163R) and field‑wired sensors/actuators, simplifying large‑channel‑count signal connections while ensuring safety and noise immunity[6][9]. As a non‑conditioning accessory, it provides secure, isolated wiring termination to protect precision SCXI hardware and reduce electromagnetic interference (EMI)[7][22].
2. Technical Parameters
| Parameter | Specification |
|---|---|
| Model / Part No. | SCXI‑1326 / 777687‑26 |
| Product Type | High‑Voltage Screw Terminal Block (SCXI Accessory) |
| Terminal Configuration | 48 screw terminals (8 banks × 6 terminals per bank, isolated)[6][9] |
| Max. Working Voltage | 300 Vrms (CAT II)[6][9] |
| Common‑Mode Isolation | 300 Vrms (bank‑to‑bank, bank‑to‑earth)[15] |
| Wiring Interface | Screw terminals (Phoenix Contact style); strain‑relief clamp for secure cabling[5][22] |
| Conductor Size | 0.2–2.5 mm² (24–14 AWG); torque: 0.5 Nm |
| Mounting | Front‑mount to SCXI module front connector[6][9] |
| Operating Temp. | 0–55 °C (32–131 °F)[4] |
| Storage Temp. | -20–60 °C (-4–140 °F) |
| Relative Humidity | 5–90% (non‑condensing)[4] |
| Dimensions | Approx. 12.7 × 7.62 × 11.18 cm (5 × 3 × 4.4 in.) |
| Weight | Approx. 0.45 kg (0.99 lb) |
| Certifications | CE, UL, IEC 61010 |
| Warranty | 3 years |
3. Product Advantages
- High‑Voltage Safety & Isolation: Rated to 300 Vrms (CAT II) with 300 Vrms bank isolation, making it ideal for high‑voltage digital I/O, temperature, and voltage applications[6][9].
- Shielded Design: Integral shielding minimizes EMI, ensuring signal integrity in noisy industrial environments[6][23].
- High‑Density Termination: 48 screw terminals (8 isolated banks) enable efficient large‑channel‑count connections, reducing panel space and wiring complexity[6][9].
- Secure Field Wiring: Screw terminals with strain‑relief clamps provide reliable mechanical and electrical connection, reducing loose‑wire failures[22].
- Module Compatibility: Directly mates with SCXI‑1162, SCXI‑1162HV, SCXI‑1163, and SCXI‑1163R modules for seamless system integration[6][9].
- User‑Friendly Operation: Front‑mount design simplifies installation, wiring, and maintenance without disrupting the SCXI chassis[23].
- Industrial Reliability: Wide operating temperature range and robust construction suit harsh industrial settings[4].
4. Precautions
- Power‑Off Wiring: Always power down the system before connecting/disconnecting field signals to avoid electric shock or hardware damage.
- Voltage Compliance: Never exceed 300 Vrms per terminal; overvoltage will damage connected SCXI modules[6][9].
- Isolation Adherence: Maintain bank isolation; do not cross‑wire isolated banks to prevent ground loops or short circuits[15].
- Conductor Sizing: Use 0.2–2.5 mm² (24–14 AWG) conductors and tighten screws to 0.5 Nm for reliable contact.
- EMI Mitigation: Ensure proper grounding of the terminal block shield and strain‑relief tab (for ≥42 Vrms) to meet safety standards and reduce noise.
- Environmental Limits: Operate within 0–55 °C and 5–90% RH (non‑condensing); avoid corrosive atmospheres or direct moisture[4].
- Module Matching: Use only with compatible SCXI modules (1162/1162HV/1163/1163R); incorrect pairing may cause measurement errors or damage[6].
- Safety Grounding: For high‑voltage applications, connect the safety earth ground to the strain‑relief tab to comply with UL 1244.
5. Product Applications
- Industrial Automation: High‑voltage digital I/O for PLCs, machine tools, robotics, and VFD‑driven systems; large‑channel temperature/voltage monitoring in automotive, metalworking, and packaging lines[9][23].
- Power & Energy: UPS systems, battery banks, renewable energy (solar/wind) inverters, and substation equipment monitoring; insulation and switch‑state monitoring in IT power systems[10].
- Test & Measurement: Automated test stands for electronic components, industrial controls, and aerospace systems; multi‑channel data acquisition in R&D labs[9][23].
- Building & Infrastructure: HVAC, fire safety, and emergency power systems in commercial buildings, airports, and rail facilities; large‑sensor‑array monitoring for structural integrity[10].
- Marine & Offshore: Shipboard and offshore platform systems (compliant with marine safety standards); harsh‑environment sensor wiring for propulsion and process control.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
| ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
| ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
| ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
| ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
| ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
| Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
| ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
| ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
| ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
| ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
| ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
| Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
| ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
| ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
| ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
| ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
| ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
| ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
| ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
| ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
| ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
| ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
| ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
| ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
| AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
| AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
| AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
| AGILENT G2630-66015 |