PXIE-1073 NI 5-Slot PXI Express Chassis with MXI-Express
Product Dimensions:
Product Description (Detailed Explanation)
The PXIe-1073 provides a high-bandwidth backplane for PXI Express and PXI hybrid-compatible modules. Its most defining characteristic is the built-in cabled PCI Express x1 link. By using a compatible PCIe-to-PXIe adapter (like the PCIe-8361) and a Thunderbolt or MXI-Express cable, a standard desktop computer serves as the system’s “brain.”
This design saves one physical slot (Slot 1), leaving all 5 slots available for peripheral I/O modules such as DAQ cards, oscilloscopes, or serial interfaces. It is an ideal solution for engineers who need the performance of PXI Express but have limited bench space or budget.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Total Slots | 5 Slots |
| Slot Compatibility | 3 PXI Express slots, 2 PXI Express Hybrid slots |
| System Bandwidth | Up to 250 MB/s (Total throughput) |
| Integrated Controller | Built-in MXI-Express (cabled PCIe x1) |
| Power Supply | Integrated AC Power (approx. 300W total) |
| Cooling | Forced-air cooling (Auto-sensing fan speed) |
| Clock Accuracy | 10 MHz Reference Clock (built-in) |
| Operating Temperature | 0°C to 50°C |
| Dimensions | 25.4 cm x 17.7 cm x 30.0 cm (approx.) |
Product Advantages (Key Benefits)
-
Integrated Link: Eliminates the cost and space of a standalone PXIe embedded controller module.
-
Compact Footprint: Small enough for desktop use or portable test kits, yet powerful enough for industrial-grade measurements.
-
Hybrid Slot Support: Allows for the use of both modern PXI Express modules and legacy PXI modules (those designed for hybrid slots), protecting your hardware investment.
-
Cost-Efficient: One of the most affordable entry points into the PXI Express ecosystem for high-speed data streaming.
-
Ease of Use: Recognized by NI MAX (Measurement & Automation Explorer) as a remote PCI bridge, making software setup straightforward.
Precautions (Important Notes)
-
Cable Sequencing: Always power on the PXIe-1073 chassis BEFORE powering on the host computer. If the computer starts first, it may fail to enumerate the PCIe bridge, and the chassis will not be recognized.
-
Slot 1 Constraint: Because the controller is integrated into the backplane, you cannot install a standard PXIe Embedded Controller (like a PXIe-8840) into this chassis.
-
Throughput Limits: The x1 Gen1 PCIe link limits the total system bandwidth to 250 MB/s. If you are using multiple high-speed digitizers or RF modules, ensure your total data rate does not exceed this bottleneck.
-
Cooling Clearance: Ensure the air intake at the bottom and exhaust at the rear are not blocked to prevent thermal shutdown.
Product Applications (Typical Use Cases)
-
Portable Field Testing: Used by field engineers for on-site diagnostics of aerospace or automotive systems where a laptop-controlled PXI system is necessary.
-
University Labs: Ideal for research environments that require precise timing and synchronization but operate on limited budgets.
-
Production Line Testing: A compact ATE (Automated Test Equipment) solution for verifying electronic components or PCBAs.
-
Data Logging: Long-term structural health monitoring where a desktop PC is used to log data from multiple PXI-6229 or PXIe-6363 modules.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
| ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
| ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
| ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
| ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
| ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
| Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
| ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
| ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
| ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
| ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
| ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
| Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
| ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
| ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
| ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
| ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
| ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
| ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
| ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
| ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
| ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
| ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
| ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
| ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
| AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
| AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
| AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
| AGILENT G2630-66015 |