Description
MS/2000PDU GE Power Distribution Unit
Product Dimensions:
Product Description (Detailed Explanation)
The MS/2000PDU is a 0U vertical mount intelligent PDU that provides reliable power distribution combined with real-time remote monitoring. It is “Network-Enabled,” meaning it features an integrated onboard controller with an Ethernet port, allowing IT administrators to access the unit via a web browser or SNMP manager.
This PDU belongs to the Metered & Switched category (depending on specific sub-configuration), but the “MS” series generally focuses on monitored capabilities at the aggregate level, providing data on current, voltage, and power consumption. It is designed to be installed in the back of a server rack, utilizing the 0U space so it does not occupy valuable RU (Rack Unit) space meant for servers and switches.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Form Factor | 0U Vertical Mount (Rack-mountable) |
| Input Voltage | AC 230/400 V (3-Phase WYE/Star) |
| Input Connection | IEC 60309 3P+N+E (16A or 32A depending on region) |
| Output Connectors | 24 Outlets (18 x IEC C13, 6 x IEC C19) |
| Monitoring | Aggregate (Unit Level) Current, Voltage, Power, Energy |
| Network Interface | 1 x Ethernet 10/100 (RJ-45) |
| Remote Protocols | HTTP, HTTPS, SNMP (v1/v2c/v3), SMTP, NTP |
| Local Display | Integrated LCD for on-site load monitoring |
| Operating Temp. | $10^{\circ}C$ to $40^{\circ}C$ |
| Casing Material | Heavy-duty Aluminum / Powder-coated Steel |
Product Advantages (Key Benefits)
-
Space Optimization: The 0U vertical design mounts to the rack posts, leaving all rack units available for computing hardware.
-
Remote Management: Built-in web interface allows users to monitor power metrics from anywhere, reducing the need for physical “walk-throughs” in the data center.
-
Alarm Thresholds: Users can set custom alerts for overcurrent or voltage fluctuations. Notifications are sent via email (SMTP) or SNMP traps to prevent downtime.
-
High Reliability: Features low-profile industrial circuit breakers and high-quality internal components designed for continuous 24/7 operation.
-
Environmental Scalability: Includes RJ-45 monitoring ports for optional sensors (temperature, humidity, or door position) to turn the PDU into a central environmental hub.
Precautions (Important Notes)
-
Load Balancing: For 3-phase models, ensure the equipment load is balanced across all three phases ($L1, L2, L3$) to prevent neutral current overload and optimize efficiency.
-
Network Security: Always change the default admin password and use HTTPS/SNMPv3 to ensure that unauthorized users cannot access the power management data.
-
Circuit Overload: Do not exceed the rated maximum current of the input plug. Monitor the LCD display during the installation of new equipment to ensure the aggregate load remains within 80% of the rated capacity (per NEC guidelines).
-
Grounding: The PDU must be properly grounded to the rack frame using the provided grounding stud to protect against surges and ensure personnel safety.
Product Applications (Typical Use Cases)
-
Enterprise Data Centers: Providing a robust power backbone for high-density blade servers and storage arrays.
-
Edge Computing: Remote monitoring of power usage in small, unmanned IT closets or branch offices where IT staff are not locally present.
-
Colocation Facilities: Used to track precise energy consumption (kWh) for billing purposes or to monitor tenant power compliance.
-
Industrial Server Racks: Powering ruggedized servers in manufacturing plants where high-voltage 3-phase power is the standard distribution.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| GE | 0207A1002-TPGA1 | GE | 118D1516G0003 |
| GE | 0207A1008TPGB1 | GE | 120-FW-2RS-C |
| GE | 0207A1102 TPAA1 | GE | 120TXA-2LS |
| GE | 0207A1200TSUA1 | GE | 123 DS200TCEAG1B MKV BOARD |
| GE | 0207AI002TPGA | GE | 124 DS200TCEAG1B MKV BOARD |
| GE | 03-1250-02 | GE | 1240V1520D |
| GE | 04019J46G0001 | GE | 125D3225G2 |
| GE | 04019J47G0001 | GE | 125D3607G1 |
| GE | 04100AC6J110A | GE | 125D3618G1 |
| GE | 0471L0303G001 | GE | 12ACR11A5A |
| GE | 0471L0304G001 | GE | 12AZ-0001-C5 |
| GE | 0471L0350G001 | GE | 12BDD15B11A |
| GE | 0517L0325AB | GE | 12BDD-15B16A |
| GE | 0621L0101G001 | GE | 12BDD16B16A |
| GE | 0621L0437-G001 | GE | 12BDD18B1A |
| GE | 0621L0442-G001 | GE | 12CEB51A3A |
| GE | 0621L0451-G001 | GE | 12CEB51B2A |
| GE | 0621L0461-G001 | GE | 12CEB52A1D |
| GE | 06B-0502-B002 #7008 | GE | 12CEH51A6A |
| GE | 07556D26G0002 | GE | 12CFD12B2A |
| GE | 0872D490G0003 | GE | 12CFV16A3A |
| GE | 1006743-903 | GE | 12CFVB11B1A |
| GE | 101C473BA-1 | GE | 12CHC11A21A |
| GE | 1023-P152A-SG608X | GE | 12CHC12A28A |
| GE | 104X109AD | GE | 12CHC21A2A |
| GE | 104X109AD102 2AG FUSE | GE | 12GCX51A11A |
| GE | 104X109AD103 2AG FUSE 1.0A | GE | 12GCX51B13A |
| GE | 104X109AD104 2AG FUSE | GE | 12HEA61A224X2 |
| GE | 104X125DC | GE | 12HFA151A9H |
| GE | 104X125DC015 DIODE MODULE | GE | 12HFA154E22F |
| GE | 104X905BA603 FACE PLATE | GE | 12IAC53B104A |
| GE | 105C9393-P2 | GE | 12IAC66K58A |
| GE | 1151GE7K72B2 | GE | 12IAC77B811A |
| GE | 115D2219G2 | GE | 12IAV53L1A |
| GE | 115D2220G2 | GE | 12IAV70B1A |
| GE | 115D2227G4 | GE | 12ICW51A2A |
| GE | 115D2230G1 | GE | 12ICW53A1A |
| GE | 115D2234G2 | GE | 12IJD52A11A |
| GE | 115D2259G3 | GE | 12IJD53C14A |
| GE | 115D2953G6 | GE | 12IJF51A2A |
| GE | 117C1059G001 | GE | 12-inch44A719977-107 |
| GE | 117D6635G2 | GE | 12NAA27AC1A |
| GE | 117D6690P3 | GE | 12NLR11E2A |
| GE | 117D6694G2 | GE | 12NLR21B2A |
| GE | 117D7374G3 | GE | 12NLR21E2A |
| GE | 117D7728G1 | GE | 12NLR21M1A |
| GE | 118D1313G1 | GE | 12PAA12A20 |
| GE | 118D1366G1 | GE | 12PJC31C67A |
| GE | 118D1377G3 | GE | 12PVD11C3A |
| GE | 118D1380G1 | GE | 12PVD21B1A |