Description
IC693MAR590B GE Fanuc Series 90-30 Mixed I/O Module
Product Dimensions:
Product Description (Detailed Explanation)
The IC693MAR590 is a versatile interface module featuring 8 Input channels and 8 Output channels.
-
Inputs: The input section is designed to handle 120V AC signals. Each input has a dedicated internal filter to reduce noise and ensure stable signal detection from field devices like pushbuttons or limit switches.
-
Outputs: The output section utilizes Relay contacts. Because these are mechanical relays, they are “voltage-free” (dry contacts), allowing the module to switch either AC or DC loads of varying voltage levels, providing high flexibility for different actuator types.
The “B” suffix indicates a specific hardware revision that maintains full backward compatibility with earlier versions while potentially offering improved component reliability.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Module Type | Mixed AC Input / Relay Output |
| Inputs | 8 Channels (120V AC) |
| Input Voltage Range | 0 to 132V AC (47 to 63 Hz) |
| Input Current | 12 mA (typical) at 120V AC |
| Outputs | 8 Channels (Relay – Form A) |
| Output Voltage Range | 5 to 250V AC / 5 to 30V DC |
| Max Output Current | 2A per point / 4A per common |
| Response Time | 30ms (Input) / 15ms (Output) |
| Isolation | 1500V between field side and logic side |
| Backplane Power | 80 mA from +5V bus; 125 mA from Relay +24V bus |
Product Advantages (Key Benefits)
-
Space Efficiency: Combines two distinct functions into a single slot, allowing for smaller PLC racks and reduced enclosure sizes.
-
Universal Switching: Relay outputs allow for a mix of AC and DC loads on the same module (though they should share the same common grouping constraints).
-
Rugged Input Protection: Designed for high-voltage AC environments typical in industrial power distribution panels.
-
Easy Troubleshooting: Features individual LED status indicators on the front panel for every input and output point, simplifying field maintenance.
-
Cost-Effective: Purchasing one mixed module is often more economical than buying separate input and output modules for low-point-count systems.
Precautions (Important Notes)
-
Relay Lifespan: Unlike solid-state outputs, mechanical relays have a finite number of operations. Avoid using this module for high-frequency PWM or rapid pulsing tasks.
-
Inductive Loads: When switching inductive loads (like motor starters or solenoids), external suppressors (RC snubbers for AC, diodes for DC) are highly recommended to prevent contact arcing and extend relay life.
-
Common Terminal Limits: Note that the total current through a single “Common” terminal must not exceed 4 Amperes, even if individual points are rated for 2 Amperes.
-
Voltage Separation: While the relays can handle different voltages, maintain proper physical separation of high and low voltage wires inside the wiring duct to prevent cross-talk.
Product Applications (Typical Use Cases)
-
Small Machinery Control: Ideal for standalone machines like industrial balers, small conveyors, or mixers where only a few sensors and actuators are needed.
-
Pump Stations: Managing start/stop signals for pumps while receiving status inputs from float switches and pressure sensors.
-
Lighting and HVAC Control: Switching contactors for high-voltage lighting banks or fan motors in building automation.
-
Interposing Relay Logic: Acting as a buffer between a high-speed PLC system and older, high-voltage field equipment.

Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| GE | 0207A1002-TPGA1 | GE | 118D1516G0003 |
| GE | 0207A1008TPGB1 | GE | 120-FW-2RS-C |
| GE | 0207A1102 TPAA1 | GE | 120TXA-2LS |
| GE | 0207A1200TSUA1 | GE | 123 DS200TCEAG1B MKV BOARD |
| GE | 0207AI002TPGA | GE | 124 DS200TCEAG1B MKV BOARD |
| GE | 03-1250-02 | GE | 1240V1520D |
| GE | 04019J46G0001 | GE | 125D3225G2 |
| GE | 04019J47G0001 | GE | 125D3607G1 |
| GE | 04100AC6J110A | GE | 125D3618G1 |
| GE | 0471L0303G001 | GE | 12ACR11A5A |
| GE | 0471L0304G001 | GE | 12AZ-0001-C5 |
| GE | 0471L0350G001 | GE | 12BDD15B11A |
| GE | 0517L0325AB | GE | 12BDD-15B16A |
| GE | 0621L0101G001 | GE | 12BDD16B16A |
| GE | 0621L0437-G001 | GE | 12BDD18B1A |
| GE | 0621L0442-G001 | GE | 12CEB51A3A |
| GE | 0621L0451-G001 | GE | 12CEB51B2A |
| GE | 0621L0461-G001 | GE | 12CEB52A1D |
| GE | 06B-0502-B002 #7008 | GE | 12CEH51A6A |
| GE | 07556D26G0002 | GE | 12CFD12B2A |
| GE | 0872D490G0003 | GE | 12CFV16A3A |
| GE | 1006743-903 | GE | 12CFVB11B1A |
| GE | 101C473BA-1 | GE | 12CHC11A21A |
| GE | 1023-P152A-SG608X | GE | 12CHC12A28A |
| GE | 104X109AD | GE | 12CHC21A2A |
| GE | 104X109AD102 2AG FUSE | GE | 12GCX51A11A |
| GE | 104X109AD103 2AG FUSE 1.0A | GE | 12GCX51B13A |
| GE | 104X109AD104 2AG FUSE | GE | 12HEA61A224X2 |
| GE | 104X125DC | GE | 12HFA151A9H |
| GE | 104X125DC015 DIODE MODULE | GE | 12HFA154E22F |
| GE | 104X905BA603 FACE PLATE | GE | 12IAC53B104A |
| GE | 105C9393-P2 | GE | 12IAC66K58A |
| GE | 1151GE7K72B2 | GE | 12IAC77B811A |
| GE | 115D2219G2 | GE | 12IAV53L1A |
| GE | 115D2220G2 | GE | 12IAV70B1A |
| GE | 115D2227G4 | GE | 12ICW51A2A |
| GE | 115D2230G1 | GE | 12ICW53A1A |
| GE | 115D2234G2 | GE | 12IJD52A11A |
| GE | 115D2259G3 | GE | 12IJD53C14A |
| GE | 115D2953G6 | GE | 12IJF51A2A |
| GE | 117C1059G001 | GE | 12-inch44A719977-107 |
| GE | 117D6635G2 | GE | 12NAA27AC1A |
| GE | 117D6690P3 | GE | 12NLR11E2A |
| GE | 117D6694G2 | GE | 12NLR21B2A |
| GE | 117D7374G3 | GE | 12NLR21E2A |
| GE | 117D7728G1 | GE | 12NLR21M1A |
| GE | 118D1313G1 | GE | 12PAA12A20 |
| GE | 118D1366G1 | GE | 12PJC31C67A |
| GE | 118D1377G3 | GE | 12PVD11C3A |
| GE | 118D1380G1 | GE | 12PVD21B1A |