Sale!

FSP-851 Honeywell Central control module

¥700.00

Notifier FSP-851(A) Series intelligent plug-in smoke detectorswith integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed inthe control panel software. Sensitivity is continuously monitoredand reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches,providing exact detector location for selective maintenancewhen chamber contamination reaches an unacceptable level.

Category:
  • Email:cindy@justwellcenter.com
  • Phone:+86 13376981664
  • Whatsapp:+86 13376981664
  • Amy

Description

Brand:Honeywell            Model number: FSP-851

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:2.5kg

Product Dimensions:

Notifier FSP-851(A) Series intelligent plug-in smoke detectorswith integral communication provide features that surpass conventional detectors. Detector sensitivity can be programmed inthe control panel software. Sensitivity is continuously monitoredand reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches,providing exact detector location for selective maintenancewhen chamber contamination reaches an unacceptable level.The FSP-851(A) photoelectric detector’s unique optical sensingchamber is engineered to sense smoke produced by a widerange of combustion sources. Dual electronic thermistors add135°F (57°C) fixed-temperature thermal sensing on the FSP851T(A). The FSP-851R(A) is a remote test capable detector foruse with DNR(A)/DNRW duct detector housings. FSP-851(A)series detectors are compatible with Notifier Onyx and CLIPseries Fire Alarm Control Panels (FACPs).FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by Notifier that greatly increases the speed ofcommunication between analog intelligent devices. Intelligentdevices communicate in a grouped fashion. If one of the devicesin the group has new information, the panel’s CPU stops thegroup poll and concentrates on single points. The net effect isresponse speed greater than five times that of earlier designs.Features• Sleek, low-profile design.• Addressable-analog communication.• Stable communication technique with noise immunity.• Low standby current.• Two-wire SLC connection.• Compatible with FlashScan® and CLIP protocol systems.• Rotary, decimal addressing (1-99 on CLIP systems, 1-159 onFlashScan systems).• Optional remote, single-gang LED accessory.• Dual LED design provides 360° viewing angle.• Visible bi-color LEDs blink green every time the detector isaddressed, and illuminate steady red on alarm (FlashScansystems only).• Remote test feature from the panel.• Walk test with address display (an address on 121 will blinkthe detector LED: 12-[pause]-1(FlashScan systems only).• Built-in functional test switch activated by external magnet.• Built-in tamper-resistant feature.• Sealed against back pressure.• Constructed of off-white fire-resistant plastic, designed tocommercial standards, and offers an attractive appearance.• 94-5V plastic flammability rating.• SEMS screws for wiring of the separate base.• Optional relay, isolator, and sounder bases.SpecificationsSensitivity: 0.5% to 2.35% per foot obscurationSize: 2.1″ (5.3 cm) high; base determines diameter.– B210LP(A): 6.1″ (15.5 cm) diameter.– B501(A): 4.1″ (10.4 cm) diameter.– B200S(A): 6.875″ (17.46 cm) diameter.– B200SR(A): 6.875″ (17.46 cm) diameter.– B224RB(A): 6.2″ (15.748 cm) diameter.– B224BI(A): 6.2″ (15.748 cm) diameter.Shipping Weight: 5.2oz. (147g).Operating Temperature range: FSP-851(A), 0°C to 49°C(32°F to 120°F). FSP-851T(A), 0°C to 38°C (32°F to 100°F).Low temperature signal for FSP-851T(A) at 45°F +/- 10°F(7.22°C +/- 5.54°C). FSP-851R(A) installed in a DNR(A)/DNRW,-20°C to 70°C (-4°F to 158°F).UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts.Relative Humidity: 10%-93% noncondensing.Thermal Ratings: Fixed-temperature setpoint 135°F (57°C).DETECTOR SPACING AND APPLICATIONSFSP-851(A) in B210LP(A) BaseB210-2951.jpgNotifier recommends spacing detectors in compliance withNFPA 72. In low airflow applications with smooth ceiling, spacedetectors 30 feet (9.144m) for ceiling heights 10 feet (3.148m)and higher. For specific information regarding detector spacing,placement, and special applications refer to NFPA 72. SystemSmoke Detector Application Guide, document A05-1003, isavailable at systemsensor.comELECTRICAL SPECIFICATIONSVoltage Range: 15-32 volts DC peak.Standby Current (max. avg.): 300μA @ 24VDC (one communication every five seconds with LED enabled).LED Current (max.): 6.5mA @ 24 VDC (“ON”).InstallationFSP-851(A) plug-in detectors use a separate base to simplifyinstallation, service, and maintenance. A special tool allowsmaintenance personnel to plug in and remove detectors withoutusing a ladder.Mount base (all base types) on an electrical backbox which is atleast 1.5″ (3.81 cm) deep. For a chart of compatible junctionboxes, see DN-60054.NOTE: 1) Because of inherent supervision provided by the SLCloop, end-of-line resistors are not required. Wiring “T-taps” orbranches are permitted for Style 4 (Class “B”) wiring. 2) Whenusing relay or sounder bases, consult the ISO-X(A) installationPage 2 of 2 — DN-6935:D • 12/08/2011-Notifier® and FlashScan® are registered trademarks of HoneywellInternational Inc.©2011 by Honeywell International Inc. All rights reserved. Unauthorized useof this document is strictly prohibited.This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice.Made in the U.S. A.sheet I56-1380 for device limitations between isolator modulesand isolator bases.Agency Listings and ApprovalsThese listings and approvals apply to the modules specified inthis document. In some cases, certain modules or applicationsmay not be listed by certain approval agencies, or listing may bein process. Consult factory for latest listing status.• UL Listed: S1115.• ULC Listed: S1115 (FSP-851A, FSP-851RA, FSP-851TA).• MEA Listed: 225-02-E .• FM Approved.• CSFM: 7272-0028:0206 .• Maryland State Fire Marshal: Permit # 2122 .• BSMI: CI313066760036.• CCCF: Certif. # 2004081801000017 (FSP-851T)Certif. # 2004081801000016 (FSP-851).• U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0(NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)).• Lloyd’s Register: 11/600013 (NFS2-640/NFS-320/NFS320C, excluding B210LP(A)).Product Line InformationNOTE: “A” suffix indicates ULC Listed model.FSP-851: Low-profile intelligent photoelectric sensor. Must bemounted to one of the bases listed below.FSP-851A: Same as FSP-851 but with ULC listing.FSP-851T: Same as FSP-851 but includes a built-in 135°F(57°C) fixed-temperature thermal device.FSP-851TA: Same as FSP-851T but with ULC listing.FSP-851R: Low-profile intelligent photoelectric sensor, remotetest capable. For use with DNRA/DNRW.FSP-851RA: Same as FSP-851R but with ULC listing. For usewith DNRA.INTELLIGENT BASESNOTE: “A” suffix indicates ULC Listed model.NOTE: For details on intelligent bases, see DN-60054.B210LP(A): Standard U.S. flanged low-profile mounting base.B210LPBP: Bulk pack of B210LP; package contains 10.B501(A): Standard European flangeless mounting base.B501BP: Bulk pack of B501; package contains 10.B200S(A): Intelligent, programmable sounder base capable ofproducing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, andcustom tone.B200SR(A): Intelligent sounder base capable of producingsound output with ANSI Temporal 3 or continuous tone.Replaces B501BH series bases in retrofit applications.B224RB(A): Plug-in System Sensor relay base. Screw terminals: up to 14 AWG (2.0 mm²). Relay type: Form-C. Rating: 2.0A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30VDC inductive.B224BI(A): Plug-in System Sensor isolator detector base.Maximum 25 devices between isolator bases .ACCESSORIESF110: Retrofit flange to convert B210LP(A) to match theB710LP(A) profile, or to convert older high-profile bases to lowprofile.F110BP: Bulk pack of F110; package contains 15.F210: Replacement flange for B210LP(A) base.RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to aU.S. single-gang electrical box. For use with B501(A) andB210LP(A) bases only.SMB600: Surface mounting kitM02-04-00:Test magnet.M02-09-00: Test magnet with telescoping handle.XR2B: Detector removal tool. Allows installation and/or removalof detector heads from bases in high ceiling applications.XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m)sections.T55-127-010: Detector removal tool without pole.BCK-200B: Black detector covers for use with FSP-851(A) only;box of 10.WCK-200B: White detector covers for use with FSP-851(A)only; box of 10.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

Honeywell CC-TAIM01
Honeywell CC-TAIX51
Honeywell CC-TAON11
Honeywell DC-PDIL51
Honeywell FCLTPSU-2430CC
Honeywell FC-PSU-240516
Honeywell FC-TIDI-1624
Honeywell FC-TSBART-1620M
Honeywell FF-SRS59242
Honeywell FF-SRS60252
Honeywell FSC
Honeywell FS-SDO-0824
Honeywell HEGS5300
Honeywell HF-75632-FCC-TAIX01CC-PDOB0
Honeywell K01-0001
Honeywell K4LCN-16
Honeywell K51195479-200
Honeywell MC-PA1H03
Honeywell MC-PDIX02
Honeywell MC-PHA001
Honeywell MC-PHAI01
Honeywell MC-TAMR0451305907-175
Honeywell MCTLPA02
Honeywell MCTLPA02MC-TLPA02
Honeywell OJ772M583580001
Honeywell SAI-1620m
Honeywell STG740
Honeywell SYS68K/CPU-30ZBE
Honeywell T8231
Honeywell T8310
Honeywell TC-0DA161
Honeywell TC100C1044
Honeywell TC-1DK161
Honeywell TC500A1052
Honeywell TC512V1
Honeywell TC-51309223-125
Honeywell TC515V2TC516
Honeywell TC6E-ML5-001
Honeywell TC800A2059
Honeywell TC803B-1004
Honeywell TC805D1008
Honeywell TC806A-1037
Honeywell TC807A1044
Honeywell TC808B1058
Honeywell TC809A1034
Honeywell TC809A1059
Honeywell TC809D1004
Honeywell TC810A1056
Honeywell TC810R1024
Honeywell TC811A-1006
Honeywell TC847A1004
Honeywell TC-CCR011
Honeywell TC-CRR014
Honeywell TCF-142-S-SC
Honeywell TC-FID161
Honeywell TC-FODA81
Honeywell TC-FX/FB-05A
Honeywell TC-FX/FB-5B
Honeywell TC-FXX131
Honeywell TC-FXX172
Honeywell TC-HAO081
Honeywell TC-IDK161
Honeywell TC-IDX161
Honeywell TC-IOLI01
Honeywell TC-IXL062
Honeywell TC-KIOL02
Honeywell TCM4351A
Honeywell TCM4351B
Honeywell TC-OAH061
Honeywell TC-ODD32
Honeywell TC-ODX161
Honeywell TCP202A
Honeywell TC-RPFM01
Honeywell TCSECE300R2
Honeywell TCSEK3MR10
Honeywell TC-TG-F1C3
Honeywell TC-XXXXX2
Honeywell TDM1.2-050-300-W1-000
Honeywell TK-FFIF01
Honeywell TK-FPCXX2
Honeywell TK-FPDXX2
Honeywell TK-FXX102
Honeywell TK-FXX132
Honeywell TK-IAH061
Honeywell TK-IAH161
Honeywell TK-IDJ161
Honeywell TK-IDW161
Honeywell TK-OAH061
Honeywell TK-OAV061
Honeywell TK-ORC081
Honeywell TK-ZLCSR1
Honeywell VR8304P4256
Honeywell XFL521
Honeywell XFL523
Honeywell XFL524

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm