Description
FBM214B P0927AH FOXBORO HART Communication Input Module
Product Dimensions:
Product Description (Detailed Explanation)
The FBM214B serves as a Fieldbus Module that provides eight channels for analog input signals. Each channel is isolated and designed to receive 4 to 20 mA signals from smart transmitters. The “B” version of the FBM214 is enhanced to provide bidirectional digital communication via the HART protocol overlaid on the analog signal.
This module acts as a bridge between the field instruments and the DCS control network. It allows the system not only to read the primary process variable (PV) but also to access secondary variables, device status, diagnostics, and configuration data from the field devices without interrupting the 4-20 mA control signal.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Input Channels | 8 Isolated Channels |
| Signal Range | 4 to 20 mA DC |
| Digital Protocol | HART (Version 5, 6, and 7 compatible) |
| Accuracy | $\pm 0.03\%$ of span |
| Resolution | 15 bits |
| Input Impedance | 250 $\Omega$ (Nominal) |
| Isolation | 600 V AC (Galvanic isolation between channels and earth) |
| Power Consumption | 3.5 Watts (Maximum) |
| Data Update Rate | 100 ms for all 8 channels (Analog) |
| Operating Temp. | $-20^{\circ}C$ to $+70^{\circ}C$ |
Product Advantages (Key Benefits)
-
Integrated Asset Management: By utilizing HART data, the FBM214B enables predictive maintenance, allowing technicians to identify failing sensors before they cause a process trip.
-
High Channel Isolation: Individual channel-to-channel isolation ensures that a ground fault or electrical noise on one field loop does not affect the performance of the other seven channels.
-
Compact Design: Part of the high-density Foxboro hardware line, allowing for more I/O points in a smaller cabinet footprint.
-
Hot-Swappable: Supports “Hot-Plug” functionality, meaning the module can be replaced while the baseplate is powered, reducing system downtime during maintenance.
-
Robust Diagnostics: The module performs continuous self-checks on its internal hardware and the health of the field loops, reporting any anomalies directly to the system operator.
Precautions (Important Notes)
-
Termination Assemblies: The FBM214B must be paired with the correct Termination Assembly (TA) for proper wiring and signal conditioning. Ensure the TA matches the P0927AH specifications.
-
HART Impedance: For reliable HART communication, the loop must have a minimum resistance of 250 $\Omega$. If the field device is powered by the module, verify the total loop impedance.
-
Environmental Sealing: If installed in a corrosive environment (Class G3), ensure the module is housed in an appropriately purged cabinet or that “Coated” versions of the hardware are used.
-
Configuration: HART device descriptions (DDs) must be loaded into the Foxboro Control Core Services (CCS) for the system to fully interpret the digital data from specific third-party transmitters.
Product Applications (Typical Use Cases)
-
Oil & Gas Processing: Monitoring pressure and temperature transmitters in refineries where remote diagnostics are essential for safety and efficiency.
-
Chemical Plants: Interfacing with complex analytical sensors that provide multi-variable data via HART (e.g., mass flow meters).
-
Power Generation: Accurate monitoring of boiler water levels and steam pressure where signal isolation is critical to prevent interference.
-
Pharmaceutical Manufacturing: Used in environments where high-precision analog data and instrument calibration tracking are required for regulatory compliance.
-
Water Treatment: Managing flow and level sensors across large-scale facilities using smart instrumentation to reduce manual field inspections.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| FOXBORO SCD2200-RTU P0924AU | FOXBORO P0926GWFBM232 | FOXBORO P0926GVFBM231 |
| FOXBORO DNBTP0971WV | FOXBORO P0926GXFBM233 | FOXBORO P0700QVFBM20 |
| FOXBORO FBM224/P0926GG | FOXBORO P0914XSFBM237 | FOXBORO P0700TWFBM21 |
| FOXBORO P0916TAFBM242 | FOXBORO P0917GZFBM240 | FOXBORO P0900HSFBM22 |
| FOXBORO P0914SQFBM201 | FOXBORO P0914TGFBM241 | FOXBORO P0900HTFBM24 |
| FOXBORO P0914SVFBM203 | FOXBORO P0914WKFBM241b | FOXBORO P0900NXFBM25 |
| FOXBORO P0916CPFCM10EF | FOXBORO P0914WMFBM241c | FOXBORO P0900HUFBM26 |
| FOXBORO P0922YHFBM201b | FOXBORO P0914WPFBM241d | FOXBORO P0900NYFBM27 |
| FOXBORO P0922YJFBM201c | FOXBORO P0914TKFBM243 | FOXBORO P0912MJFBM33 |
| FOXBORO P0922YKFBM201d | FOXBORO P0914XNFBM246 | FOXBORO P0902XAFBM41 |
| FOXBORO P0926EQFBM202 | FOXBORO P0970BCDNBI | FOXBORO P0902XBFBM42 |
| FOXBORO P0922UAFBM203b | FOXBORO P0971WVDNBT | FOXBORO P0150HQ |
| FOXBORO P0922UDFBM203c | FOXBORO P0960AWCP30 | FOXBORO P0151HD |
| FOXBORO P0914SYFBM204 | FOXBORO P0960JACP40 | FOXBORO P0151JS |
| FOXBORO P0914XGFBM205 | FOXBORO P0961FRCP60 | FOXBORO P0151RC |
| FOXBORO P0916CQFBM206 | FOXBORO P0400DAFBM01 | FOXBORO P0151WW |
| FOXBORO P0914TDFBM207 | FOXBORO P0400YCFBM02 | FOXBORO P0152KL |
| FOXBORO P0914WHFBM207b | FOXBORO P0400YDFBM03 | FOXBORO P0155AX |
| FOXBORO P0917GYFBM207c | FOXBORO P0400YEFBM04 | FOXBORO P0156KD |
| FOXBORO P0914TBFBM208 | FOXBORO P0400YFFBM05 | FOXBORO P0156KM |
| FOXBORO P0914XLFBM212 | FOXBORO P0400YGFBM06 | FOXBORO P0170NS |
| FOXBORO P0914XNFBM213 | FOXBORO P0400YHFBM07 | FOXBORO P0170NX |
| FOXBORO P0914XQFBM214 | FOXBORO P0400YJFBM08 | FOXBORO P0170NY |
| FOXBORO P0922VUFBM215 | FOXBORO P0400YKFBM09 | FOXBORO P0170PC |
| FOXBORO P0922VVFBM216 | FOXBORO P0400YLFBM10 | FOXBORO P0170PE |
| FOXBORO P0914TRFBM217 | FOXBORO P0400YMFBM11 | FOXBORO P0170PL |
| FOXBORO P0916RHFBM219 | FOXBORO P0400YNFBM12 | FOXBORO P0170SR |
| FOXBORO P0922VWFBM218 | FOXBORO P0400YPFBM13 | FOXBORO P0170TF |
| FOXBORO P0917HAFBM220 | FOXBORO P0400YQFBM14 | FOXBORO P0176RU |
| FOXBORO P0917HDFBM223 | FOXBORO P0400YRFBM15 | FOXBORO P0176RV |
| FOXBORO P0926GGFBM224 | FOXBORO P0400YSFBM16 | FOXBORO P0176RW |
| FOXBORO P0922QSFBM228 | FOXBORO P0400YTFBM17 | FOXBORO P0176SA |
| FOXBORO P0926GUFBM230 | FOXBORO P0400YVFBM18 | FOXBORO P0176UC |
| FOXBORO P0176VT |