Description
F2-08TRS AutomationDirect DL205 8-Channel Isolated Relay Output
Product Dimensions:
Product Description (Detailed Explanation)
The F2-08TRS belongs to the Koyo-designed DL205 PLC family. Unlike standard relay modules that share a common return, this module features individual isolation for each of its 8 channels.
This means each relay has its own dedicated “Common” terminal, allowing you to switch different voltages (e.g., 24VDC on one channel and 120VAC on another) within the same module without electrical interference. Each output consists of a Form A (SPST-NO) relay contact.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Number of Channels | 8 Isolated Outputs |
| Output Type | Relay, Form A (Normally Open) |
| Isolation Voltage | 1500V (Input to Output), 500V (Between Channels) |
| Maximum Voltage | 7–30 VDC / 7–125 VAC |
| Maximum Current | 7A per point / 56A per module |
| Response Time | ON: 10 ms / OFF: 10 ms |
| Expected Life | 100,000 operations at rated load |
| Backplane Power | 5VDC: 670 mA (All relays ON) |
| Fuses | None (External fusing recommended) |
Product Advantages (Key Benefits)
-
Point-to-Point Isolation: Prevents ground loops and allows the mixing of different power sources (AC and DC) on a single module.
-
High Current Capacity: Rated at 7 Amps per point, it can directly drive large solenoids, small motors, and heavy-duty contactors without needing interposing relays.
-
Removable Terminal Block: Facilitates quick maintenance; you can replace the module without disconnecting every individual wire.
-
Diagnostic LEDs: Features clear status indicators for each channel, allowing technicians to verify PLC output signals at a glance.
-
Reliability: Built-in surge suppression is not included, but the rugged mechanical relays are well-suited for high-noise industrial environments.
Precautions (Important Notes)
-
Inductive Load Protection: When switching inductive loads (motors, solenoids, or coils), you must use external suppression (flyback diodes for DC or varistors/RC snubbers for AC) to prevent arcing and extend relay contact life.
-
Backplane Power Limit: This module consumes a significant amount of 5V power from the DL205 base (up to 670mA). Always calculate the total power budget of your base (e.g., D2-06B-1) to ensure the power supply is not overloaded.
-
Mechanical Wear: Relays have a finite mechanical lifespan. For high-frequency switching applications (e.g., PWM), use solid-state modules instead of the F2-08TRS.
-
Minimum Load: Ensure the connected load draws at least 5mA; otherwise, the contact resistance might prevent the load from activating reliably over time.
Product Applications (Typical Use Cases)
The F2-08TRS is ideal for applications requiring high-power switching and signal diversity:
-
Motor Starter Control: Activating the coils of Size 1 or Size 2 motor starters in industrial pumping or conveyor systems.
-
Mixed Voltage Manifolds: Controlling a pneumatic valve bank where some valves are 24VDC and others are 120VAC.
-
Lighting Control: Switching high-wattage HID or LED lighting circuits in warehouses or greenhouses.
-
Alarm Annunciation: Driving external sirens, strobe lights, or heavy-duty buzzers that require significant current.

Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
| ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
| ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
| ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
| ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
| ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
| Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
| ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
| ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
| ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
| ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
| ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
| Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
| ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
| ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
| ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
| ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
| ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
| ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
| ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
| ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
| ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
| ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
| ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
| ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
| AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
| AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
| AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
| AGILENT G2630-66015 |