Description
EI803F ABB Ethernet Interface Module
Product Dimensions:
Product Description (Detailed Explanation)
The EI803F provides the AC 800F controller with a standardized Ethernet connection. It allows the controller to communicate with DigiVis operator stations and the Control Builder F engineering tool.
By using the EI803F, the controller can be integrated into a local area network (LAN) for system-wide data exchange. It supports high-speed data transmission and is designed to handle the critical communication requirements of industrial automation, including the downloading of configuration data and the real-time transmission of process variables and alarms.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Series | Freelance / AC 800F |
| Transmission Rate | 10/100 Mbps (Autosensing) |
| Interface Type | 10Base-T / 100Base-TX |
| Connector Type | RJ45 |
| Protocol Support | TCP/IP, UDP, ARP, ICMP |
| Max. Cable Length | 100 meters (Standard Cat5e or higher) |
| Current Consumption | Approx. 150 mA (Internal 5V) |
| Isolation | Galvanic isolation from the controller backplane |
| Diagnostic LEDs | Link, Activity, Speed, and Module Status |
Product Advantages (Key Benefits)
-
Seamless Integration: Designed specifically for the AC 800F backplane, requiring no external cabling for power or internal data bus connection.
-
Standardized Networking: Uses standard Ethernet technology, allowing for the use of off-the-shelf industrial switches and fiber optic converters for long-distance runs.
-
High Reliability: Built for industrial environments with high electromagnetic compatibility (EMC) standards to ensure stable communication in noisy factory settings.
-
Plug-and-Play Configuration: Easily recognized by the Freelance engineering software, simplifying the network setup and IP addressing process.
-
High Throughput: Sufficient bandwidth to handle dense process data, large faceplate updates, and rapid alarm reporting simultaneously.
Precautions (Important Notes)
-
Network Security: As an Ethernet-based device, it is crucial to place the EI803F behind an industrial firewall or within a secure “Control Network” layer to prevent unauthorized access.
-
Switch Quality: Always use Managed Industrial Ethernet Switches (such as the ABB RS series or Stratix) to ensure proper traffic prioritization (QoS) for control data.
-
Firmware Matching: Ensure the module firmware is compatible with the Freelance software version (e.g., Version 9.x or 2013/2016/2019) to avoid communication dropouts.
-
IP Conflicts: Carefully manage the IP address range. A duplicate IP address on the control network can cause the AC 800F controller to become unresponsive.
Product Applications (Typical Use Cases)
-
DCS Communication Backbone: Connecting the AC 800F controller to the Freelance System Bus for interaction with Operator Stations (HIS).
-
Cross-Controller Communication: Allowing multiple AC 800F controllers to exchange interlocking signals or process data over a shared Ethernet network.
-
Engineering & Diagnostics: Providing the port for engineers to connect a laptop for online troubleshooting, logic modification, and firmware updates.
-
Third-Party Integration: Acting as the hardware layer for Modbus TCP or other Ethernet-based protocols to communicate with external PLCs, analyzers, or smart power meters.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ABB | 07DC92 GJR5252200R0101 | ABB | 5STP2665N0024 |
| ABB | 07KT98 GJR5253100R0270 | ABB | 5STP27H1800 |
| ABB | 07LE90 | ABB | 5STP27H2801 |
| ABB | 100-250V50/60HZ-D | ABB | 5STP2842L0024 |
| ABB | 100-250V50/60HZ-DC | ABB | 5STP28L4200 |
| ABB | 100-250V50/60HZ-DC | ABB | 5STP3328L0003 |
| ABB | 10332-00505 | ABB | 5STP3328L0005 |
| ABB | 10332-00655 | ABB | 5STP3328L0011 |
| ABB | 120M8-NT-6 | ABB | 5STP34H1601 |
| ABB | 19160/29160N ASC-29160N/DELL2 | ABB | 5STP38N4000 |
| ABB | 19160/29160N ASC-29160N/DELL2 | ABB | 5STP38N4200 |
| ABB | 1Q1SY-Cabled | ABB | 5STP4200 |
| ABB | 1SAP250300R0001 AI523 | ABB | 5STP45N2800 |
| ABB | 220V-230V50Hz | ABB | 5STP45Q2800 |
| ABB | 24-30Vac/dc | ABB | 70M6-NT-6 |
| ABB | 250Vac/dc | ABB | 95M8-NT-6 |
| ABB | 35M6-NT-6 | ABB | A110-30-11*110V 50Hz/110-120V |
| ABB | 38SC98000HR615 | ABB | A110-30-11*220-230V |
| ABB | 3ASD573001A1 YPP110A | ABB | A12-30-10*220-230V |
| ABB | 3ASD573001A13 | ABB | A145-30-11*110V |
| ABB | 3ASD573001A13 YPK112A | ABB | A145-30-11*220-230V |
| ABB | 3BHE024577R0101/PP C907 | ABB | A16-30-10*110V |
| ABB | 3BSC980004R784 | ABB | A16-30-10*220-230V |
| ABB | 3BSC980006R136 | ABB | A185-30-11*110V |
| ABB | 3BSE018135R1 CI858K01 | ABB | A210-30-11*110V |
| ABB | 3BSE020510R1 DO801 | ABB | A210-30-11*220-230V |
| ABB | 3BSE022362R1 DI803 | ABB | A260-30-11*110V |
| ABB | 3BSE022364R1 DO802 | ABB | A260-30-11*220-230V |
| ABB | 3BSE024388R4 PFXA401SF | ABB | A26-30-10*110V |
| ABB | 3GZF303135-3 | ABB | A26-30-10*220-230V |
| ABB | 50Hz/110-120V | ABB | A300-30-11*220-230V |
| ABB | 50Hz/230-240V | ABB | A30-30-10*220-230V |
| ABB | 50HZ/230-240V | ABB | A40-30-10*220-230V |
| ABB | 57310001-CC DSPC171 | ABB | A63-30-11*110V50/110-120V60HZ |
| ABB | 57310001-CC DSPC171 | ABB | A63-30-11*220V-230V50Hz/230-240V60Hz |
| ABB | 57310001-GP | ABB | A9-30-10*110V |
| ABB | 5SHY3545L0010 3BHB013088R0001 | ABB | A9-30-10*220-230V |
| ABB | 5STP 18H4200 | ABB | A9-40-00 |
| ABB | 5STP03D6500 | ABB | A95-30-11*220-230V 50Hz/230-240V |
| ABB | 5STP03X6500 | ABB | ACS150/310/355 |
| ABB | 5STP04D4200 | ABB | ACS510 |
| ABB | 5STP06D2800 | ABB | ACS550 |
| ABB | 5STP08F6500 | ABB | ACS580 |
| ABB | 5STP10D2303 | ABB | ACS880-01/04 |
| ABB | 5STP12F4200 | ABB | ACS880-07 |
| ABB | 5STP16F2200 | ABB | AF1250-30-11*100-250V |
| ABB | 5STP16F2800 | ABB | AF145-30-11*100-250V |
| ABB | 5STP16F2801 | ABB | AF185-30-11*100-250V |
| ABB | 5STP18F1800 | ABB | AF260-30-11*100-250V |
| ABB | 5STP18F1801 | ABB | AF265-30-11-13 |