BAS98ATEX3008X OTB122 ZELLWEGER Signal Converter/Transmitter
Product Dimensions:
Product Description (Detailed Explanation)
The OTB122 serves as an interface and junction unit for the Searchline Excel gas detection system. Its primary role is to provide a secure environment for terminal connections and to facilitate the communication between the sensor heads (Transmitter/Receiver) and the central control system.
-
Integrated Design: It often houses the electronics required to convert raw sensor signals into a standard industrial format (such as 4-20mA or digital signals).
-
ATEX Certification: The “X” at the end of the certificate number (BAS98ATEX3008X) indicates that there are “Special Conditions for Safe Use,” typically relating to installation requirements or electrostatic risks.
-
Ruggedized Housing: It is built to withstand extreme offshore and onshore industrial environments.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Manufacturer | Zellweger Analytics (Honeywell) |
| Model Number | OTB122 |
| ATEX Certificate | BAS98ATEX3008X |
| Protection Type | Ex d (Flameproof) or Ex e (Increased Safety) depending on configuration |
| Enclosure Material | Marine Grade Aluminum or 316 Stainless Steel |
| Output Signal | 4-20 mA / RS485 / Modbus (Configuration dependent) |
| Input Voltage | 18 VDC to 32 VDC |
| Operating Temperature | -40°C to +65°C |
| Ingress Protection | IP66 / IP67 |
Product Advantages (Key Benefits)
-
Hazardous Area Reliability: Specifically engineered for Zone 1 and Zone 2 environments, ensuring safety in the presence of explosive gases.
-
Simplified Maintenance: The OTB122 provides a centralized point for testing and calibration without having to disturb the alignment of the open-path sensor heads.
-
Corrosion Resistance: The high-grade material construction makes it ideal for saltwater environments (offshore platforms) and chemical plants.
-
Signal Stability: Provides excellent shielding against Electromagnetic Interference (EMI), which is crucial for long-distance signal transmission in industrial sites.
Precautions (Important Notes)
-
Special Conditions of Use: As per the “X” suffix in the ATEX certificate, installers must strictly follow the manual regarding cable entry types and potential static charging hazards.
-
Flameproof Paths: For “Ex d” versions, ensure that the flameproof joints (threaded covers) are clean and undamaged. Never apply grease that could harden and prevent gas movement to the sensor.
-
Seal Integrity: All unused cable entries must be sealed with certified Ex-rated stopping plugs to maintain the explosion-proof integrity.
-
Power Down for Service: Always isolate the power before opening the enclosure in a hazardous area to prevent ignition risks.
Product Applications (Typical Use Cases)
The OTB122 is used wherever Searchline Excel systems are installed to protect large areas:
-
Oil & Gas Refineries: Monitoring perimeter lines or fence-line detection for escaping hydrocarbon clouds.
-
Offshore Platforms: Detecting gas leaks across production decks where point detectors might be impractical due to wind.
-
LNG Terminals: Monitoring storage tanks and loading jetties for cryogenic gas leaks.
-
Petrochemical Pipelines: Protecting valve stations and compressor stations along long-distance pipelines.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ACCURAY 8-061588-002 | ADEMCO ADR1600E | ADTEC AX-1000-AMII |
| ACCURAY QA-3-017948-003 | ADEMCO HRM60N500 | ADTRAN 4200663L1 |
| ACCURAY 086370-001 | ADEMCO VISTA-250FBP | Advanced ICP-16L |
| ACCURAY 086158-004 | ADEPT Adept 101 | ADVANCED DUO-I8030NM |
| ACCURAY 085221-001 | ADEPT AWCII 040 | ADVANCED 9R918W3 |
| ACCURAY 061552-001 | ADEPT EJI90340-40000 | ADVANCED SB1391-C-R-C-A |
| Accu-Sort BoxPC-126M | ADEPT SCARA 550 | Advanced MN3150272-006 |
| ACME TA-1-81008 | ADEPT 10330-11350 | Advantech PPC-105T-ABAR |
| ACME TA-1-32406 | ADEPT 10332-12350 | Advantech FPM-3171G-XCE |
| ACME TA-1-81306 | ADEPT ASSY 10350-00100 | Advantech WOP-2100T-N2AE |
| ACME T-1-53011 | ADEPT ADEPT AWCII 040 | ADVANTEST R3265A |
| ACME TA-2-81003 | ADEPT AWCII-040 | ADVANTEST BLF-022828 ACC-BOARD |
| Acquisition AL81G | ADEPT 90402-40013/XY-HRS013-S1B1-AD | ADVANTEST BLG-022829 |
| ACS ACS-0400-PS | ADEPT 90402-40013 | ADVANTEST R6244 |
| ACS SB1381-B-E-R-A-PM2 | ADEPT 90400-20055/XY-HRS-055M201 | Advantest D3185A |
| ACS SB1381-C-E-R-A | ADEPT 90400-02100-EXTB01AD | AE RAPID-F |
| ACS SB214ND-F-9 | ADEPT 90400-70030 | AEG 41-94384 |
| ACS MOTION CONTROL HSSI-I016 | ADEPT 90400-71031 | AEG M907-122 |
| ACT TCS-SRME-6210-CD-RTM | ADEPT 10330-11350 | AEG DEP220 |
| ACTION AIOI8100 | ADIXEN FM36122 | AEG DTA200 |
| ACTUS POWER NPSA-TMTA-222 | ADP ADP-1 | AEG DTA201 |
| ACUITY 002-PV900 | ADRIVE E642B-MGB-K-01 | AEG PC-A984-145 |
| ACUITY 010-PV9040 | ADTEC 3000III | AEG MM-PM22-200 |
| ADC FPL-72RP0W-1448B | ADTEC AXR-2000III | AEG MM-PM21400C |
| ADDI-DATA APCI-1710 | ADTEC AX-2000EUII-N | AEG MM-PM21-400 |
| AEG AS-P892-000 | AEG M135-H60A-OYOY-G3 | AEG PC-E984-381 |
| AEG M344-MKOA-4001 | Aerotech U100M-A-40-F5 | AEG MM-PM22-300 |
| AEG CGC13-TB | AFE DP320T-BC | AGIE MJG-2129 |
| AGILENT G2630-66015 |