Description
Woodward 8280-192 Digital Speed Control
Product Dimensions:
This manual describes the Woodward EGCP-2 Engine Generator ControlPackage models 8406-115 and 8406-116 (9–32 Vdc maximum input voltagerange).Control Electrical Ratings nominal supply voltage range 10–29 Vdc (12 or 14 volt systems) max. power consumption at rated voltage 20 W max. PT input voltage range 150–300 Vac rms (8406-115) 50–150 Vac rms (8406-116) max. CT current input range 0–6 A rms max. generator frequency range 40–70 Hz
Woodward Part Numbers: 8406-115 EGCP-2 Engine Generator Control, 150-300 Vac PT input 8406-116 EGCP-2 Engine Generator Control, 50-150 Vac PT input Power Supply Rating 9–32 Vdc (SELV) Maximum input voltage range Power Consumption less than or equal 13 W nominal, 20 W maximum Input Supply Voltage Input Supply Current 12 V (nominal) 1.08 A 24 V (nominal) 542 mA 32 V 406 mA PT input 50-150 Vac, 8406-116 150-300 Vac, 8406-115 CT input 0–5 Arms Generator Frequency Range 40–70 Hz Magnetic Pickup 100–15000 Hz Discrete Inputs (8) 5 mA source current when CLOSED to Switch Common(65) Process input 4–20 mA, 1–5 Vdc Temperature and pressure inputs 0–200 Ω sensors, 4–20 mA transducer, or 0–5 Vtransducer Speed Bias ±3 Vdc, .5–4.5 Vdc, 5V peak 500 Hz PWM Voltage Bias ±1 Vdc, ±3 Vdc, ±9 Vdc Discrete Outputs (Relay Outputs) 10 A, 250 Vac Resistive 1/3 HP, 125 Vac (7.2 Amp, 0.4-0.5 P.F.) 10 Amp, 30 Vdc Resistive Communication Ports RS-485, RS-422 Ambient Operating Temperature –20 to +70 °C (–4 to +158 °F)(around outside of EGCP-2Chassis) Storage Temperature –40 to +105 °C (–40 to +221 °F) Humidity 95% at +20 to +55 °C (+68 to +131 °F) Mechanical Vibration SV2 5–2000 Hz @ 4 G and RV1 10–2000 Hz @ .04 G²/Hz Mechanical Shock US MIL-STD 810C, Method 516.2, Procedure I (basicdesign test), Procedure II (transit drop test, packaged),Procedure V (bench handling) Equipment Classification Class 1 (grounded equipment) Air Quality Pollution Degree II Installation Overvoltage Category III Ingress Protection Will meet the requirements of IP56 as defined in IEC529when installed in a suitable atmospherically ventedenclosure. Also meets Type 4 requirements.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
5501-381 | WOODWARD | 5466-1047 | WOODWARD |
8200-226 | WOODWARD | 5466-1049 | WOODWARD |
8250-565 | WOODWARD | 5466-253 | WOODWARD |
8272-582 | WOODWARD | 5501-365 | WOODWARD |
8290-189 | WOODWARD | 723PLUS | WOODWARD |
8290-191 | WOODWARD | 8200-203 | WOODWARD |
8290-195 | WOODWARD | 8235-622 | WOODWARD |
8405-307 | WOODWARD | 8251-766 | WOODWARD |
8406-113 | WOODWARD | 8405-011 | WOODWARD |
8407-522 | WOODWARD | 8405-084 | WOODWARD |
8440-1706 | WOODWARD | 9904-041 | WOODWARD |
8440-1831 | WOODWARD | 9905-028 | WOODWARD |
PCU-DPIO V4.6.3 | WOODWARD | 9905-392 | WOODWARD |
1680-2004 | WOODWARD | 9905-463 | WOODWARD |
8235-154 | WOODWARD | 9905-792 | WOODWARD |
8250-573 | WOODWARD | 9905-990 | WOODWARD |
8273-140 | WOODWARD | 9907-1106 | WOODWARD |
8440-2165 | WOODWARD | 9907-186 | WOODWARD |
8901-457 | WOODWARD | 9907-205 | WOODWARD |
8923-1633 | WOODWARD | 9907-345 | WOODWARD |