Description
1746-NIO4V A-B 2-channel voltage output analog combination module
Product Dimensions:
Product Description (Detailed Explanation)
The 1746-NIO4V features 2 Analog Input channels and 2 Analog Output channels. This module is ideal for smaller systems where rack space is limited but both sensing and control capabilities are required.
-
Inputs: The two input channels are universal and can be configured for various voltage or current ranges (though typically used for voltage in this “V” designated model).
-
Outputs: The two output channels are specifically designed for Voltage Output (e.g., 0 to 10V DC). This makes it perfect for controlling actuators that require a voltage reference, such as variable frequency drives (VFDs) or proportional valves.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Module Type | Combination Analog Input / Voltage Output |
| Number of Inputs | 2 Channels (Differential) |
| Number of Outputs | 2 Channels (Voltage only) |
| Input Voltage Range | $\pm 10V$ DC, 1 to 5V DC, 0 to 5V DC, 0 to 10V DC |
| Output Voltage Range | $\pm 10V$ DC (nominal) |
| Resolution | 14-bit (Input) / 14-bit (Output) |
| Backplane Current (5V) | 55 mA |
| Backplane Current (24V) | 115 mA |
| Step Response | 10 ms (Input) / 2.5 ms (Output) |
| Isolation | 500V DC between user I/O and backplane |
Product Advantages (Key Benefits)
-
Space Efficiency: By combining inputs and outputs into a single slot, it reduces the overall chassis size and system cost.
-
High Resolution: With 14-bit resolution, it provides precise control and sensing for sensitive industrial processes.
-
Differential Inputs: The inputs are differential, which helps reject common-mode noise, ensuring signal integrity in electrically “noisy” factory environments.
-
Simplified Spares: Maintenance teams only need to stock one module type to cover both input and output functions for a specific loop.
Precautions (Important Notes)
-
Output Loading: Ensure the load impedance on the voltage outputs is at least 1000 ohms. Loading the output too heavily can result in inaccurate voltage levels or module damage.
-
External Power: This module draws significant current from the 24V DC backplane bus. Verify that your SLC 500 power supply (e.g., 1746-P1 or P2) has enough remaining capacity.
-
Shielding: Use twisted-pair, shielded cable for all analog signals. The shield should be grounded at only one end (usually at the PLC rack) to prevent ground loops.
-
DIP Switch Configuration: The input types must be configured via internal DIP switches before the module is inserted into the rack.
Product Applications (Typical Use Cases)
-
VFD Speed Control: Sending a 0-10V signal to a motor drive while receiving a 0-10V speed feedback signal.
-
Temperature/Pressure Loops: Measuring a process variable via an analog transmitter and outputting a control signal to a motorized damper or valve.
-
Tension Control: Monitoring web tension in paper or film processing and providing a corrective voltage signal to a brake or clutch controller.
-
Level Management: Using ultrasonic level sensors (input) to trigger and modulate a variable-speed pump (output).
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| AB 1756-0B16E | AB 1756-DMD30 | AB 1756-IB32 |
| AB 1756-0F4 | AB 1756-DNB | AB 1756-IB32/A |
| AB 1756-0X8I | AB 1756-DNB/A | AB 1756-IF16 |
| AB 1756-A10 | AB 1756-DNB/A/B | AB 1756-IF16/A |
| AB 1756-A13 | AB 1756-DNB/B | AB 1756-IF161 |
| AB 1756-A17 | AB 1756-DNB/C1756-DNB/D | AB 1756-IF16H |
| AB 1756-A4 | AB 1756-DNB/D | AB 1756-IF4FXOF2F |
| AB 1756-A7 | AB 1756-DNB1 | AB 1756-IF6CIS |
| AB 1756-BA11 | AB 1756-EN2T | AB 1756-IF6I |
| AB 1756-BA2 | AB 1756-EN2T/C | AB 1756-IF8 |
| AB 1756-CFM | AB 1756-EN2T/D | AB 1756-IF8H |
| AB 1756-CN2 | AB 1756-EN2TR | AB 1756-IF8U |
| AB 1756-CN2/B | AB 1756-EN2TR/B | AB 1756-IG16 |
| AB 1756-CN21 | AB 1756-EN3TR | AB 1756-IH16I |
| AB 1756-CN2R | AB 1756-ENBT | AB 1756-IM16I |
| AB 1756-CN2R/B | AB 1756-ENBT/A | AB 1756-IM16I1203-CN1 |
| AB 1756-CNB | AB 1756-ENET | AB 1756-IN16 |
| AB 1756-CNB/A/B/C/D | AB 1756-EWEB | AB 1756-IR6I |
| AB 1756-CNB/D | AB 1756-HSC | AB 1756-IRT8I |
| AB 1756-CNB/E | AB 1756-HSC1 | AB 1756-IT6I |
| AB 1756-CNBR | AB 1756-HYD02 | AB 1756-IT6I2 |
| AB 1756-CNBR/A/D | AB 1756-IA16/A | AB 1756-IV16 |
| AB 1756-CNBR/D | AB 1756-IA32 | AB 1756-IV32 |
| AB 1756-CNBR/E | AB 1756-IB16 | AB 1756-L1M1 |
| AB 1756-CPR2 | AB 1756-IB16/A | AB 1756-L35E |
| AB 1756-DHRIO | AB 1756-IB16D | AB 1756-L55M12 |
| AB 1756-DHRIO/C | AB 1756-IB16I | AB 1756L55M13 |
| AB 1756-DHRIO/D | AB 1756-IB16ISOE | AB 1756-L55M13 |
| AB 1756-DHRIO/E | AB 1756-IB16SOE | AB 1756-L55M14 |
| AB 1756L55M22 | AB 1756-L55M16 | AB 1756L55M16 |
| AB 1756-L55M23 | AB 1756L55M23 | AB 1756-L55M22 |



