Sale!

1746-IB32 A-B SLC 500 Digital Input Module

¥1,000.00

Brand:Allen-Bradley   

Model number:1746-IB32

Colour:new                Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:1.0kg

Category:
  • Email:cindy@justwellcenter.com
  • Phone:+86 13376981664
  • Whatsapp:+86 13376981664
  • Amy

Description

1746-IB32 A-B SLC 500 Digital Input Module(32-Channel)

Product Dimensions:

Product Description (Detailed Explanation)

The 1746-IB32 provides 32 discrete input points in a single-slot module. It operates on a 24V DC Sinking configuration, meaning the module provides a path to the negative common for the field devices.

Due to its high density (32 points in one slot), it does not use a standard removable terminal block. Instead, it features a specialized 40-pin connector on the front, which typically requires a pre-wired cable or a custom interface module (like the Allen-Bradley 1492 series) to facilitate wiring to the field devices.

Product Parameters (Technical Specifications)

Parameter Category Specification
Number of Inputs 32 Points
Voltage Category 24V DC Sink
Operating Voltage Range 15V to 30V DC
Off-state Voltage (Max) 5.0V DC
On-state Current (Min) 2.0 mA
Nominal Input Current 5.1 mA at 24V DC
Input Delay (Max) 8 ms (Off-to-On and On-to-Off)
Backplane Current (5V DC) 0.050 A (50 mA)
Backplane Current (24V DC) 0.000 A (External power required for field side)

Product Advantages (Key Benefits)

  • Space Efficiency: By providing 32 points in a single slot, it allows for a smaller physical footprint of the PLC rack, which is ideal for space-constrained control cabinets.

  • Cost Reduction: Reduces the number of I/O chassis and power supplies needed by maximizing the density per slot.

  • Standardized 24V Logic: Uses the industry-standard 24V DC logic level, ensuring compatibility with a vast majority of industrial sensors and proximity switches.

  • Optical Isolation: Features galvanic isolation between the field-side electronics and the backplane, protecting the CPU from electrical surges or noise on the field wiring.

Precautions (Important Notes)

  • No RIUP (Removal Under Power): Unlike newer Logix systems, the SLC 500 chassis does not support hot-swapping. You must turn off the rack power before removing or inserting this module.

  • Wiring Complexity: Because it uses a 40-pin header rather than screw terminals, you must use compatible 1492-CABLE interface cables. Wiring directly to the pins without a breakout board is prone to errors and physical damage.

  • Heat Dissipation: High-density modules generate more heat. Ensure the cabinet has proper ventilation, and follow the manufacturer’s guidelines regarding slot placement and spacing.

  • Sinking/Sourcing Identification: This is a Sinking module. Ensure your field devices are wired as “Sourcing” (PNP) to ensure the circuit completes correctly.

Product Applications (Typical Use Cases)

  • Material Handling: Monitoring large arrays of photo-eyes and limit switches on conveyor systems.

  • Packaging Machinery: Interfacing with high numbers of push-buttons and safety interlocks on automated bagging or bottling lines.

  • Automotive Assembly: Collecting status signals from various jigs and pneumatic cylinders across a long production station.

  • Modernization Projects: Expanding existing SLC 500 systems where spare rack slots are limited, but more I/O points are required.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

AB 1756-0B16E AB 1756-DMD30 AB 1756-IB32
AB 1756-0F4 AB 1756-DNB AB 1756-IB32/A
AB 1756-0X8I AB 1756-DNB/A AB 1756-IF16
AB 1756-A10 AB 1756-DNB/A/B AB 1756-IF16/A
AB 1756-A13 AB 1756-DNB/B AB 1756-IF161
AB 1756-A17 AB 1756-DNB/C1756-DNB/D AB 1756-IF16H
AB 1756-A4 AB 1756-DNB/D AB 1756-IF4FXOF2F
AB 1756-A7 AB 1756-DNB1 AB 1756-IF6CIS
AB 1756-BA11 AB 1756-EN2T AB 1756-IF6I
AB 1756-BA2 AB 1756-EN2T/C AB 1756-IF8
AB 1756-CFM AB 1756-EN2T/D AB 1756-IF8H
AB 1756-CN2 AB 1756-EN2TR AB 1756-IF8U
AB 1756-CN2/B AB 1756-EN2TR/B AB 1756-IG16
AB 1756-CN21 AB 1756-EN3TR AB 1756-IH16I
AB 1756-CN2R AB 1756-ENBT AB 1756-IM16I
AB 1756-CN2R/B AB 1756-ENBT/A AB 1756-IM16I1203-CN1
AB 1756-CNB AB 1756-ENET AB 1756-IN16
AB 1756-CNB/A/B/C/D AB 1756-EWEB AB 1756-IR6I
AB 1756-CNB/D AB 1756-HSC AB 1756-IRT8I
AB 1756-CNB/E AB 1756-HSC1 AB 1756-IT6I
AB 1756-CNBR AB 1756-HYD02 AB 1756-IT6I2
AB 1756-CNBR/A/D AB 1756-IA16/A AB 1756-IV16
AB 1756-CNBR/D AB 1756-IA32 AB 1756-IV32
AB 1756-CNBR/E AB 1756-IB16 AB 1756-L1M1
AB 1756-CPR2 AB 1756-IB16/A AB 1756-L35E
AB 1756-DHRIO AB 1756-IB16D AB 1756-L55M12
AB 1756-DHRIO/C AB 1756-IB16I AB 1756L55M13
AB 1756-DHRIO/D AB 1756-IB16ISOE AB 1756-L55M13
AB 1756-DHRIO/E AB 1756-IB16SOE AB 1756-L55M14
AB 1756L55M22 AB 1756-L55M16 AB 1756L55M16
AB 1756-L55M23 AB 1756L55M23 AB 1756-L55M22

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm