Description
1606-XLDNET8 A-B DeviceNet Dedicated Power Supply
Product Dimensions:
Product Description (Detailed Explanation)
The 1606-XLDNET8 is part of the high-performance Bulletin 1606 family. Unlike standard 24V industrial power supplies, this unit is specifically “DeviceNet-rated.” It provides high-quality DC power while filtering out the high-frequency interference common in industrial environments that can corrupt digital bus communications.
The unit is designed for DIN-rail mounting and features a slim, space-saving design. It includes specialized circuitry to handle the peak current demands of DeviceNet modules and actuators, ensuring that voltage remains stable even during high-traffic or high-load conditions on the trunk line.
Product Parameters (Technical Specifications)
| Parameter Category | Specification |
| Input Voltage | AC 100-240V (Auto-ranging) |
| Output Voltage | DC 24V (Fixed/Optimized for DeviceNet) |
| Output Current | 8 Amps |
| Output Power | 192 Watts |
| Efficiency | > 90% |
| Inrush Current | Limited by internal NTC/Active circuitry |
| Isolation | 3000 VAC (Input to Output) |
| Mounting | 35mm DIN Rail (IEC 60715) |
| Operating Temp. | $-25^{\circ}C$ to $+70^{\circ}C$ (Derating above $60^{\circ}C$) |
| Certifications | UL Listed, CE, ODVA Conformance Tested |
Product Advantages (Key Benefits)
-
ODVA Compliance: Fully tested and approved to meet Open DeviceNet Vendors Association (ODVA) specifications for power supplies, ensuring 100% network compatibility.
-
Low Noise/Ripple: Extremely low output ripple prevents electromagnetic interference from causing “bus-off” errors or data packet loss on the network.
-
Large Power Reserve: The 8A output capacity is sufficient to power multiple nodes, sensors, and low-power actuators on a standard DeviceNet trunk line.
-
Active Inrush Current Limiting: Prevents circuit breakers from tripping during initial power-up, even when multiple units are installed in the same cabinet.
-
High Reliability: Features comprehensive protection against short circuits, overloads, and over-voltage (OVP), with high MTBF (Mean Time Between Failures).
Precautions (Important Notes)
-
Current Limits: DeviceNet cables (Thin or Thick) have specific current carrying capacities. Ensure that the 8A provided by this supply does not exceed the rating of your specific cable segments.
-
Single Point Grounding: To prevent ground loops, the negative terminal (V-) of the DeviceNet power supply should be connected to the system ground at only one point in the entire network.
-
Ventilation: Maintain a minimum clearance of 40mm above and below the unit and 15mm on the sides to ensure adequate convection cooling.
-
Voltage Adjustment: Do not significantly adjust the output voltage away from 24V, as DeviceNet nodes are sensitive to over-voltage conditions which can damage communication transceivers.
-
Output Wiring: Use appropriately sized wire (typically 14-12 AWG for the main output) to minimize voltage drop over long trunk lines.
Product Applications (Typical Use Cases)
-
Automotive Assembly Lines: Providing stable power for distributed I/O and pneumatic valves across extensive DeviceNet architectures.
-
Material Handling: Powering conveyor systems where sensors and motor starters are networked via DeviceNet.
-
Packaging Machinery: Used in high-speed machines where signal integrity is critical and electrical noise from VFDs (Variable Frequency Drives) must be filtered.
-
Food & Beverage: Installed in control cabinets for bottling and processing lines to ensure reliable communication with distributed instrumentation.
-
Remote I/O Stations: Serving as the dedicated power source for remote racks and blocks in large industrial plants.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| AB 1756-0B16E | AB 1756-DMD30 | AB 1756-IB32 |
| AB 1756-0F4 | AB 1756-DNB | AB 1756-IB32/A |
| AB 1756-0X8I | AB 1756-DNB/A | AB 1756-IF16 |
| AB 1756-A10 | AB 1756-DNB/A/B | AB 1756-IF16/A |
| AB 1756-A13 | AB 1756-DNB/B | AB 1756-IF161 |
| AB 1756-A17 | AB 1756-DNB/C1756-DNB/D | AB 1756-IF16H |
| AB 1756-A4 | AB 1756-DNB/D | AB 1756-IF4FXOF2F |
| AB 1756-A7 | AB 1756-DNB1 | AB 1756-IF6CIS |
| AB 1756-BA11 | AB 1756-EN2T | AB 1756-IF6I |
| AB 1756-BA2 | AB 1756-EN2T/C | AB 1756-IF8 |
| AB 1756-CFM | AB 1756-EN2T/D | AB 1756-IF8H |
| AB 1756-CN2 | AB 1756-EN2TR | AB 1756-IF8U |
| AB 1756-CN2/B | AB 1756-EN2TR/B | AB 1756-IG16 |
| AB 1756-CN21 | AB 1756-EN3TR | AB 1756-IH16I |
| AB 1756-CN2R | AB 1756-ENBT | AB 1756-IM16I |
| AB 1756-CN2R/B | AB 1756-ENBT/A | AB 1756-IM16I1203-CN1 |
| AB 1756-CNB | AB 1756-ENET | AB 1756-IN16 |
| AB 1756-CNB/A/B/C/D | AB 1756-EWEB | AB 1756-IR6I |
| AB 1756-CNB/D | AB 1756-HSC | AB 1756-IRT8I |
| AB 1756-CNB/E | AB 1756-HSC1 | AB 1756-IT6I |
| AB 1756-CNBR | AB 1756-HYD02 | AB 1756-IT6I2 |
| AB 1756-CNBR/A/D | AB 1756-IA16/A | AB 1756-IV16 |
| AB 1756-CNBR/D | AB 1756-IA32 | AB 1756-IV32 |
| AB 1756-CNBR/E | AB 1756-IB16 | AB 1756-L1M1 |
| AB 1756-CPR2 | AB 1756-IB16/A | AB 1756-L35E |
| AB 1756-DHRIO | AB 1756-IB16D | AB 1756-L55M12 |
| AB 1756-DHRIO/C | AB 1756-IB16I | AB 1756L55M13 |
| AB 1756-DHRIO/D | AB 1756-IB16ISOE | AB 1756-L55M13 |
| AB 1756-DHRIO/E | AB 1756-IB16SOE | AB 1756-L55M14 |
| AB 1756L55M22 | AB 1756-L55M16 | AB 1756L55M16 |
| AB 1756-L55M23 | AB 1756L55M23 | AB 1756-L55M22 |