1400-PM-ACC Allen-Bradley Digital Interface Module

PT Configuration
To find your specific wiring
mode (Delta, wye, Open
Delta, Direct Connect), see
the power monitor user
manual.
Control Power 1 Amp Fuse
We recommend that
Control Power is from a
separate source than the
Voltage Inputs.
CT Configuration
To find your specific wiring
mode (Delta, wye, Open
Delta), see the power
monitor user manual.

Category:
  • Email:cindy@justwellcenter.com
  • Phone:+86 13376981664
  • Whatsapp:+86 13376981664
  • Amy

Description

Brand:Allen-Bradley   Model number:1400-PM-ACC

Colour:new                  Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:2.5kg

Product Dimensions:

Include a shorting terminal block in the CT secondary circuit when wiring CTs and the power monitor. The shorting terminal block serves as an intermediary connection point where
wiring modifications can be safely made.
The shorting terminal block has a modified factory-installed 9-pole jumper that connects the white terminal blocks (neutral CT connections) to the ground terminal block.
To modify the wiring of the power monitor side of the shorting block safely, when the primary conductor is energized, the positive leads of the CTs (black terminal blocks) must be
shorted to ground. Never open a secondary winding of a CT if the primary conductor is energized.
1. To short the CTs, remove the 2-pole jumpers from the gray terminal blocks and insert them into the positive and neutral terminal blocks for each CT connection (for
example, I1+ and I1- for line 1 current).
2. Once the CTs are properly shorted, wiring modifications can be made to the power monitor side of the shorting block.
3. After the intended wiring changes have been made, remove the 2-pole jumpers from the CT connections and reinsert them into the gray terminal blocks for storage.
For replacement 2-pole jumpers, use catalog number 1492-CJP4-2.
Based on specific customer application, additional potential transformers can be required. See Additional Resources on page 2.

PowerMonitor 5000 unit, publication 1426-UM001 Provides installation instructions, wiring diagrams, configuration, and specifications for
PowerMonitor 5000 units.
For the PowerMonitor 1000 unit, see the user manual, publication 1408-UM002.
Provides installation instructions, wiring diagrams, configuration, and specifications for
PowerMonitor 1000 units with catalog numbers 1408-BC3A-485, 1408-BC3A-ENT,
1408-TS3A-485, 1408-TS3A-ENT, 1408-EM3A-485, 1408-EM3A-ENT.
For the PowerMonitor 500 unit, see the user manual, publication 1420-UM001. Provides installation instructions, wiring diagrams, configuration, and specifications for
PowerMonitor 500 units.
Product Certifications website, rok.auto/certifications. Rockwell Automation maintains current declarations of conformity, certificates, and other certification
documents on its website.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

AB 1746-OB16
AB 1746-OB16E
AB 1746-OB32
AB 1746-OB32E
AB 1746-OB8
AB 1746-OBP16
AB 1746-OG16
AB 1746-OV16
AB 1746-OV32
AB 1746-OW16
AB 1746-OW16/C
AB 1746-OW16/C/D
AB 1746-OW4
AB 1746-OW8
AB 1746-OX8
AB 1746-P1
AB 1746-P2
AB 1746-P2/C
AB 1746-P3
AB 1746-P4
AB 1746-P5
AB 1746-P6
AB 1746-P7
AB 1746SC-NI8U
AB 1746SC-OAP8I
AB 1747-ACN15
AB 1747-ACNR15
AB 1747-ACNR15/A
AB 1747-ASB
AB 1747-ASB/A
AB 1747-ASB1747-L511
AB 1747-BA
AB 1747-BSN
AB 1747-BSN1771-IFE
AB 1747-CP3/A
AB 1747-DCM
AB 1747-KE
AB 1747-KFC15
AB 1747-L30C
AB 1747-L40F
AB 1747-L511
AB 1747-L511/B
AB 1747-L514
AB 1747-L524
AB 1747-L524/C
AB 1747-L53
AB 1747-L531
AB 1747-L531/E
AB 1747-L531/L532/L533
AB 1747-L532
AB 1747-L532/D
AB 1747-L532/D/E
AB 1747-L532/E
AB 1747-L533
AB 1747-L541
AB 1747-L541/B
AB 1747-L541/B/C
AB 1747-L541/C
AB 1747-L542
AB 1747-L542/B
AB 1747-L542/C
AB 1747-L543
AB 1747-L543/C
AB 1747-L55
AB 1747-L551
AB 1747-L551/B
AB 1747-L551/C
AB 1747-L552
AB 1747-L552/C
AB 1747-L553
AB 1747-L553/B
AB 1747-L553/C
AB 1747-M1
AB 1747-M11
AB 1747-M12/A
AB 1747-M13
AB 1747-M15
AB 1747-M2
AB 1747-M4
AB 1747-NI4
AB 1747-PSD
AB 1747-SCNR
AB 1747-SDN
AB 1747-SN
AB 1747-SN17
AB 1747-UIC
AB 1756-0B16E
AB 1756-0F4
AB 1756-0X8I
AB 1756-A10
AB 1756-A13
AB 1756-A17
AB 1756-A4
AB 1756-A7
AB 1756-BA11
AB 1756-BA2
AB 1756-CFM
AB 1756-CN2
AB 1756-CN2/B
AB 1756-CN21
AB 1756-CN2R
AB 1756-CN2R/B
AB 1756-CNB
AB 1756-CNB/A/B/C/D
AB 1756-CNB/D
AB 1756-CNB/E
AB 1756-CNBR
AB 1756-CNBR/A/D
AB 1756-CNBR/D
AB 1756-CNBR/E
AB 1756-CPR2
AB 1756-DHRIO
AB 1756-DHRIO/C
AB 1756-DHRIO/D
AB 1756-DHRIO/E
AB 1756-DMD30
AB 1756-DNB
AB 1756-DNB/A
AB 1756-DNB/A/B
AB 1756-DNB/B
AB 1756-DNB/C1756-DNB/D
AB 1756-DNB/D
AB 1756-DNB1
AB 1756-EN2T
AB 1756-EN2T/C
AB 1756-EN2T/D
AB 1756-EN2TR
AB 1756-EN2TR/B
AB 1756-EN3TR
AB 1756-ENBT
AB 1756-ENBT/A
AB 1756-ENET
AB 1756-EWEB
AB 1756-HSC
AB 1756-HSC1
AB 1756-HYD02
AB 1756-IA16/A
AB 1756-IA32
AB 1756-IB16
AB 1756-IB16/A
AB 1756-IB16D
AB 1756-IB16I
AB 1756-IB16ISOE
AB 1756-IB16SOE
AB 1756-IB32
AB 1756-IB32/A
AB 1756-IF16
AB 1756-IF16/A
AB 1756-IF161
AB 1756-IF16H
AB 1756-IF4FXOF2F
AB 1756-IF6CIS
AB 1756-IF6I
AB 1756-IF8
AB 1756-IF8H
AB 1756-IF8U
AB 1756-IG16
AB 1756-IH16I
AB 1756-IM16I
AB 1756-IM16I1203-CN1
AB 1756-IN16
AB 1756-IR6I
AB 1756-IRT8I
AB 1756-IT6I
AB 1756-IT6I2
AB 1756-IV16
AB 1756-IV32
AB 1756-L1M1
AB 1756-L35E
AB 1756-L55M12
AB 1756L55M13
AB 1756-L55M13
AB 1756-L55M14
AB 1756L55M16
AB 1756-L55M16
AB 1756L55M22
AB 1756-L55M22
AB 1756L55M23
AB 1756-L55M23

Additional information

Weight 0.1 kg
Dimensions 10 × 10 × 10 cm