Description
140-V2-ENT A-B Ethernet Communication Module
Product Dimensions:
Product Description (Detailed Explanation)
The 140-V2-ENT module is a dedicated hardware interface that enables ControlWave controllers to communicate over standard TCP/IP Ethernet networks. While some ControlWave CPUs have built-in Ethernet, the 140-V2-ENT is used either as an expansion to add a second independent network or to upgrade older CPU configurations that lack native networking.
This module supports simultaneous communication with multiple hosts and devices. It allows the RTU to serve as a high-speed data hub, bridging field-level I/O data to higher-level SCADA systems, HMI displays, and enterprise management software. It supports advanced features like Report-by-Exception, which ensures data is only sent when changes occur, drastically reducing network congestion.
Product Parameters (Technical Specifications)
Product Advantages (Key Benefits)
-
Dual-Network Redundancy: By adding this module to a controller with a built-in port, you can create a redundant network architecture for mission-critical applications.
-
Open Architecture: Supports standard Modbus TCP, making it easy to integrate Emerson RTUs with third-party HMIs, PLCs, and cloud gateways.
-
Remote Management: Enables remote program downloading, diagnostic monitoring, and firmware updates via FTP/Telnet, reducing the need for site visits.
-
Extreme Durability: Like the rest of the ControlWave line, this module is rated for harsh outdoor temperatures, making it superior to commercial-grade networking hardware.
-
Scalable Communication: Efficiently handles high-volume data traffic while maintaining the low-latency required for real-time control loops.
Precautions (Important Notes)
-
Configuration Jumper: Ensure the hardware jumpers on the module are correctly set for the intended backplane slot and communication mode before installation.
-
IP Address Management: Conflicts on the network can cause the RTU to drop communication. Always use static IP addresses for industrial RTUs to ensure consistent SCADA polling.
-
Cybersecurity: Since this module opens the controller to IP networks, it is critical to use industrial firewalls or VPNs. Avoid exposing the module directly to the public internet.
-
Cable Quality: Use high-quality Category 5e (Cat5e) or Category 6 (Cat6) shielded twisted-pair cables to protect against electromagnetic interference (EMI) in industrial environments.
Product Applications (Typical Use Cases)
-
Oil & Gas Pipeline Monitoring: Linking remote RTUs at valve sites to a central SCADA host via satellite or cellular Ethernet gateways.
-
Smart Grid Substations: Integrating electrical protection relays and power meters into the ControlWave system using Modbus TCP.
-
Large-Scale Water Distribution: Networking multiple pump stations across a city to a centralized control room for synchronized pressure management.
-
Plant-Wide Integration: Connecting a ControlWave Micro on a factory floor to the company’s ERP or MES system for real-time production tracking.
-
Remote Site Diagnostics: Providing a high-speed link for engineering teams to perform “over-the-shoulder” troubleshooting from a central office.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| AB 1756-0B16E | AB 1756-DMD30 | AB 1756-IB32 |
| AB 1756-0F4 | AB 1756-DNB | AB 1756-IB32/A |
| AB 1756-0X8I | AB 1756-DNB/A | AB 1756-IF16 |
| AB 1756-A10 | AB 1756-DNB/A/B | AB 1756-IF16/A |
| AB 1756-A13 | AB 1756-DNB/B | AB 1756-IF161 |
| AB 1756-A17 | AB 1756-DNB/C1756-DNB/D | AB 1756-IF16H |
| AB 1756-A4 | AB 1756-DNB/D | AB 1756-IF4FXOF2F |
| AB 1756-A7 | AB 1756-DNB1 | AB 1756-IF6CIS |
| AB 1756-BA11 | AB 1756-EN2T | AB 1756-IF6I |
| AB 1756-BA2 | AB 1756-EN2T/C | AB 1756-IF8 |
| AB 1756-CFM | AB 1756-EN2T/D | AB 1756-IF8H |
| AB 1756-CN2 | AB 1756-EN2TR | AB 1756-IF8U |
| AB 1756-CN2/B | AB 1756-EN2TR/B | AB 1756-IG16 |
| AB 1756-CN21 | AB 1756-EN3TR | AB 1756-IH16I |
| AB 1756-CN2R | AB 1756-ENBT | AB 1756-IM16I |
| AB 1756-CN2R/B | AB 1756-ENBT/A | AB 1756-IM16I1203-CN1 |
| AB 1756-CNB | AB 1756-ENET | AB 1756-IN16 |
| AB 1756-CNB/A/B/C/D | AB 1756-EWEB | AB 1756-IR6I |
| AB 1756-CNB/D | AB 1756-HSC | AB 1756-IRT8I |
| AB 1756-CNB/E | AB 1756-HSC1 | AB 1756-IT6I |
| AB 1756-CNBR | AB 1756-HYD02 | AB 1756-IT6I2 |
| AB 1756-CNBR/A/D | AB 1756-IA16/A | AB 1756-IV16 |
| AB 1756-CNBR/D | AB 1756-IA32 | AB 1756-IV32 |
| AB 1756-CNBR/E | AB 1756-IB16 | AB 1756-L1M1 |
| AB 1756-CPR2 | AB 1756-IB16/A | AB 1756-L35E |
| AB 1756-DHRIO | AB 1756-IB16D | AB 1756-L55M12 |
| AB 1756-DHRIO/C | AB 1756-IB16I | AB 1756L55M13 |
| AB 1756-DHRIO/D | AB 1756-IB16ISOE | AB 1756-L55M13 |
| AB 1756-DHRIO/E | AB 1756-IB16SOE | AB 1756-L55M14 |
| AB 1756L55M22 | AB 1756-L55M16 | AB 1756L55M16 |
| AB 1756-L55M23 | AB 1756L55M23 | AB 1756-L55M22 |